Installation - Models IHF033, IHF045 and IHF055
Ground
The machine must be placed on a flat, solid surface (metal base, concrete or solid ground). It is recommended that the machine be anchored on the provided places (1) in the base, especially in case of a plinth. Refer to Figure 6.
1
CHM2180N
1Mounting Bolt Holes
Figure 6
The machine must be placed entirely level. For easy maintenance it is recommended to keep a minimal distance of 23.62 in. (600 mm) between the wall and the back of the machine.
If several machines are placed next to each other, there should be a minimal distance of 1.18 in. (30 mm) between each machine.
Electrical Installation Requirements - Models IHF033, IHF045 and IHF055
Machine with steam heating or boiler fed machines without additional electrical heating
| 220V 3AC | 380V 3AC + N |
|
|
|
| 16 A | 16 A |
|
|
|
Machine with electrical heating |
| |
|
|
|
| 220V 3AC | 380V 3AC + N |
|
|
|
9 kW | 25 A | 16 A |
|
|
|
12 kW | 40 A | 20 A |
|
|
|
15 kW | 50 A | 25 A |
|
|
|
18 kW | 50 A | 32 A |
|
|
|
21 kW | N/A | 40 A |
|
|
|
24 kW | N/A | 40 A |
|
|
|
Table 1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 10 |