Installation
Models IWF033, IWF040, IWF055 and IWF075 (2-speed)
CAUTION
Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.
SW020
Surface
The machine must be securely fixed on a flat surface (metal base, concrete or solid ground). The anchoring is to be done on the 4 provided places in the holes on the corner of the base. (See Mounting Bolt Hole Locations). Refer to Figure 21.
1
CHM2102N
1Mounting Bolt Holes
Figure 21
The machine must be placed entirely level. For easy maintenance it is recommended to keep a minimal distance of 23.62 in. (600 mm) between the wall and the back of the machine.
If several machines are placed next to each other, there should be a minimal distance of 1.18 in. (30 mm) between each machine.
Anchoring to Metal Base
The machines must be fixed on a metal base which is securely anchored on a concrete base. Refer to Figure 22.
| 1 | 2 |
| 7 | 3 |
|
| |
| 2 |
|
6 | 3 | 4 |
| ||
| 5 |
|
|
| CHM2103N |
1 | Machine Base |
|
2 | Nut |
|
3 | .625 in. (M16) |
|
Washer |
| |
| 1.57 in. x 0.60 in. x 0.15 in. |
|
4 | (40 mm x 17 mm x 4 mm) |
|
Bolt |
| |
5 | .625 in. x 2.5 in. (M16x60 mm) |
|
Bolt |
| |
6 | .625 in. (M16) |
|
Concrete Base |
| |
| 15.74 in. (400 mm) (Models IWF033 and | |
| IWF040), and 21.65 in. (550 mm) | |
| (Model IWF055), and 27.55 in. (700 mm) | |
7 | (Model IWF075) |
|
Metal Base |
|
Figure 22
Machine bolts should be
37 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT |