_Foryour safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or loss of life.
-Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance.
-WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Clear the room, building or area of all occupants.
•Immediately call your gas supplier from a neighbor'sphone. Followthe gas suppliers instructions.
•If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
|
| REQUIREMENTS |
| Tools Required for Installation: | |
1. | l/4in, nutdriver |
|
2. | 318 in. socket with ratchet. | _ |
3, | 3/8 in. open end wrench. |
|
4.7/16 in. socket with ratchet.
5.9/16 in, open end wrench.
6.
7.Carpenter'slevel.
ELECTRICAL REQUIREMENTS
CIRCUIT - Individual, properly polarized and grounded
15amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker•
POWER SUPPLY - 2 wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current.
OUTLET RECEPTACLE - Propedy grounded
GROUNDING REQUIREMENTS
[] Impropar connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded.
. The washer MUST be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current.
. Since your washer is equipped with a power supply cord having an
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42 inches (107 cm) of your washer'swater inlet. The faucets MUST be 3/4 inch (1.9 cm) garden hose type so inlet hoses can be connected. Water pressure MUST be between 10 and 120 pounds per square inch (maximum unbalance pressure, hot vs. cold, 10 psi.) Your water department can advise you of your water pressure. The hot water temperature should be about 120 degrees F (49 degrees C).
DRAIN REQUIREMENTS
1.Drain capable of eliminating 17 gals (64.3 L) per minute.
2.A standpipe diameter of
3.The standpipe height above the floor should be: Minimum height: 24 in. (61 cm)
Maximum height: 96 in. (244 cm)
96 in.
(244 cm) Max.
II
_j
_ _ BACK =___
NOTE:
Drain hose attached to the washer can reach a 58 in. (147 cm) high standpipe• For higher standpipe use hose P/N 131461201, available from Sears
Parts and Service. If drain is less than 24 in. (61 cm), install a siphon break kit, DIV 26110285320, available from Sears Parts and Service.
2