20 electrolux installation

than +5°C and higher than +35°C, as it may affect the performance of the appliance.

Fitting the vent hose

A special stacking kit is available throughTo simplify the installation, there is a choice of vent outlets: one at the back, the others in the left and right- hand side.

Connect the hose to whichever is the more convenient by pulling the ring nut

(A)from the vent outlet at the back, screwing it on to the hose and pushing it firmly back into place. The unused vents should now be sealed with the special snap covers provided.

Once connected to the dryer, run the vent hose to the desired outlet point, ensuring that the run’s overall length is less than 2 m, and that it contains no more than two bends. As to the outlet itself, if you have decided on a fixed wall/window grille, a good local builder’s merchant should be able to supply you with the necessary fittings and installation advice.

It is important not to connect the vent hose to, for example, a cooker hood, or a chimney or flue pipe designed to carry the exhaust from

P1028

A

A

P1027

a fuel burning appliance.

Advice: If the hose is long and the room temperature low, the moisture might condense to water inside the hose. This is an unavoidable natural phenomenon. To prevent this water from Iying in the hose or flowing back into the tumble dryer, it is advisable to drill a small hole (dia. 3 mm) in the lowest point of the hose and to place a small container below it.(See picture, point B).

P1056B

Note that to avoid condensation problems, it is essential that the dryer be fitted with the flexible hose to carry its “exhaust” at least beyond the kitchen units; preferable outside the kitchen.

In order to prevent the appliance from overheating, it is important that the steam exhaust is unobstructed. Therefore, in case of a permanent hose fitted to an exterior wall or ceiling, it must be ensured an exhaust capacity of at least 150 m3/h.

If the dryer is fitted next to kitchen units, make sure that the vent hose is not squashed. If the hose is partially

Image 20
Contents Tumble Dryer EDE 36150W Qxp 2007-10-02 0844 Welcome to the world of Electrolux Contents Installation Safety InformationGeneral safety Child safety UseProduct description Control panel Use First Use Daily UseSelect the required programme Programme Option buttonsSelect the Half power Select the StartDrying hints Laundry weights Maximum loadsDrying programmes Programme Type Options Description of programme LaundryCare and cleaning External cleaningMalfunction Possible cause Solution Something not workingModel, serial number and purchase date Technical data Minute Positioning InstallationUnpacking Fitting the vent hose Fuel burning applianceDoor reversal Stacking kitElectrical connection Environment concerns Packaging materialsOld machine Ecological hintsGuarantee conditions IndonesiaElectrolux guarantee/customer service 136 904