Installation Instructions

Read these instructions with care.

These instructions are provided for use by qualified installers, in addition the installation must comply with:

In the United States, in accordance with the National Electric Code ANSI/NFPA70 – latest edition and any State, Municipal or local codes.

In Canada, in accordance with the Canadian Electric Code C22.1 – latest edition and any Provincial, Municipal or local codes

Electrical

The dryer comes with a three cord power supply cord fitted with a 5-15P (plug), a receptacle should be installed in a location accessible after the dryer is installed.

Grounding

Some local codes may require a separate ground. In such cases the required ground wire, clamp and screw must be purchased separately.

NEVER ground the dryer to plastic plumbing lines, gas lines or water pipes.

NOTE: IF IN DOUBT ABOUT ANY OF THE ABOVE

CONSULT A QUALIFIED ELECTRICIAN

Where to put your dryer

Check local codes before choosing a location. Some codes do not permit installation in a garage, closet, mobile home or bedroom.. DO NOT install the dryer in an area where gasoline or other flammable materials are kept or stored.

W hen operating the dryer, there has to be adequate ventilation to avoid the back flow of gases into the room from appliances burning other fuels, including open fires.

Minimum installation clearances.

 

Closet

Closet (alternative)

Under Counter

Sides

¾” (15 mm)

0

¾” (15 mm)

Top

½” (10 mm)

4” (100 mm)

½” (10 mm)

Rear

¾” (15 mm)

¾” (15 mm)

¾” (15 mm)

Front

¾” (15 mm)

¾” (15 mm)

not applicable

Vent Opening –

 

 

 

Distance from

6” (150mm)

2” (50mm)

not applicable

Top of closet

 

 

 

If installed in a closet it must have the following dimensions and have two ventilation openings each having and area 72 sq. ins. (450 sq. cm) located) 2” (50mm or 6” (150mm) from top[see table] and 6” (150mm) from bottom of door.

It must NEVER be installed in a closet with a solid door.

The dryer has adjustable height feet, use these to level the dryer after fitting into its final position.

RV/Marine Installations

W hen locating the appliance in a towable trailer or watercraft, position the dryer over the axles or mid-ship where movement is at a minimum. Block the dryer to prevent extreme movement or tipping.

12

Image 12
Contents Care, Use and Installation booklet ContentsPage « AVERTISSEMENT. Risque d’incendie.» Advertencia Riesgo de Incendi oSave These Instruction Dryer Description Control PanelStart and Programs Choosing a ProgramProgram What it does How to set it ProgramsFabric Care Easy Iron ProgramLaundry Sorting your laundryWash care labels Special clothing items Drying timesRegularCottons EN When you should Switch off the electricity Clean the filter after each cycleCleaning the drum Cleaning the dryerProblem Possible causes / Solutions Dryer won’t startIt is taking a long time to dry Where to put your dryer RV/Marine InstallationsExhaust Ducting Stacking KitsAlternative stacking kit Ariston ONE-YEAR Limited Warranty USA & Canada only