CONNECT

ELECTRICAL

CORD

Access

covet"

Strain relief

(not supplied with dryer)

3-wire or 4-wire Plug Connection

Four-wire cord is required for mobile homes or where codes do not permit

grounding through neutral.

1.Remove access cover from rear of dryer.

2.Use a strain relief and insert end of power cord through power supply hole.

3.Use the three screws from envelope located in the drum to attach the remaining power cord wires to the terminal block as follows:

Red wire to "LI" terminal.

Black wire to "L2" terminal.

White wire to Neutral terminal.

4-wirePlug Only--Remove ground screw and detach ground wire from bulkhead. Attach power cord ground (green) wire to rear bulkhead using ground screw. Attach free ground wire, previously attached with ground screw, with white wire to the neutral (center) terminal on the terminal block.

4.Tighten all screws and reinstall access cover removed in step 1.

3-wireCord Installed

4-wire Cord Installed

 

Ground

'%1"

;_

"L2"

"LI"

wire

 

 

Neutral _r_

 

II

Neutral

"L2"

Orou dJ

 

 

76

 

White

Red

White

 

 

Black

Green

Black

POSITION AND

LEVEL DRYER

Place dryer in position, adjust all

legs (4) until dryer is level side to

side and front to back.

Image 3
Contents Wrench Remove Parts Clean Dryer DrumBefore Duct Tape10.16 cm 2 6.35 cm Connect Dryer to Exhaust SystemExhaust System Materials Maximum Exhaust LengthConnect Electrical Cord Position Level DryerStrain relief Not supplied with dryer About Ground Wires Important SafetyInstallation Requirements 6 cm 19. cm 15.4 AW 39.1 cm10.21cm 23.5 59.7 cm 71.1 cm With leveling legs turned into base