American Dryer Corp HBG76 Gas Pressure Testing, Steam Information, Gas Pressure Test Procedure

Page 15

Gas Pressure Testing _________________

For proper operation, the gas pressure must be correct, consistent and maintained at the gas pressure rates shown on page 14. Provisions are made at the gas valve for taking gas pressure readings.

There are 2 types of devices used to measure gas pressure. They are the spring/mechanical type gauge and the manometer. The use of the spring/mechanical type gauge is not recommended because they are very easily damaged and are not always accurate. The preferred type of gauge is the manometer because it is a simple device to use and is highly accurate. A manometer is simply a glass or transparent plastic tube with a scale graduated in inches or millibar. When it is filled with water and pressure is applied, the water in the tube rises, showing the exact gas pressure.

Gas Pressure Test Procedure

Turn gas cock in gas supply line to “OFF” position.

50 Hz dryers: Back out miniature screw inside pressure tap and attach manometer.

60 Hz dryers: Install pressure tap and attach manometer. Turn gas cock to “ON” position.

Start the dryer in Heat Mode and wait for ignition. Gas manifold pressure should be as shown on page 14.

Once test is complete, turn gas cock to “OFF” position. Remove manometer. Tighten screw inside the pressure tap or install plug.

Turn gas cock to “ON” position and check for leaks with soap solution with main burner “ON.”

Steam Information ____________________

It is your responsibility to have all plumbing connections made by a qualified professional to ensure that the steam plumbing installation is adequate and conforms with local, state, and country regulations or codes.

Care must be exercised when leveling steam dryers into final position. After leveling the dryer, check the downward pitch of the heat exchanger from front to rear with a level. Likewise, check the downward pitch of the return condensate manifold toward its outlet part. Absence of these downward pitches will result in probable water hammer and premature heat exchanger fracture and leakage.

The presence of condensate in the steam will cause water hammer and subsequent heat exchanger failure. The steam supply connection must be taken from the top of a well-dripped steam main. If the supply run-out to the dryer exceeds 25 feet (7.6 meters), it should be dripped just before the control valve with a proper trap and dirt pocket.

Important: Failure to comply with the requirements stipulated in this manual can result in component failure, which will void the warranty.

Steam Coil pH Level

The normal pH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For steel type steam coils the pH level must be maintained between a value of 9.5 to 10.5. These limits are set to limit the acid attack of the steam coils.

Important: Coil failure due to improper pH level will void the warranty.

113615 -1

www.amdry.com

15

Image 15
Contents American Dryer Corporation HBG76HBG76 Table of Contents What To Do If You Smell Gas Safety PrecautionsCE Only 69.37 cm SpecificationsSpecifications Dryer Enclosure Requirements Installation ProceduresUnpacking/Setting Up Location RequirementsExhaust Requirements Fresh Air Supply RequirementsVertical Venting Outside Ductwork ProtectionSingle Dryer Venting Horizontal VentingElectrical Service Specifications Gas and Steam Models Only Electrical InformationElectrical Requirements Electrical Connections Single-Phase 1ø Wiring Connections/HookupElectric Models Only GroundingCE and Australian Dryers Gas InformationPiping/Connections Heat Input/Gas Consumption/Orifice Injector DataSteam Coil pH Level Gas Pressure TestingGas Pressure Test Procedure Steam InformationWater Information Coin Models Preparation for Operation/Start-UpPreoperational Test Preoperational InstructionsShutdown Instructions Service/Parts InformationWarranty Information Non-Coin ModelsRoutine Maintenance Standard Label AGA Label CE Label Data Label Information113615 ADC Part No 07/24/08

HBG76 specifications

American Dryer Corp (ADC) has established itself as a leading provider of high-quality laundry equipment, and their HBG76 model is a prime example of innovative design and advanced technology in commercial dryers. The HBG76 is engineered for efficiency, versatility, and durability, making it an ideal choice for laundromats, hotels, and other commercial laundry operations.

One of the main features of the HBG76 is its robust construction. Built with high-grade materials, the dryer offers exceptional longevity and reliable performance, capable of withstanding the rigors of frequent use. Its exterior is designed not only for durability but also for ease of maintenance, with convenient access points for servicing and cleaning.

The HBG76 incorporates state-of-the-art drying technologies aimed at maximizing efficiency and reducing energy consumption. One notable aspect is its powerful yet efficient heating system, which rapidly raises and maintains optimal temperature levels. This feature allows for shorter drying cycles, ultimately increasing throughput and profitability for operators.

Additionally, the HBG76 features advanced airflow technology, ensuring that every load receives uniform drying. With strategically placed ventilations, the dryer enhances air circulation within the drum, preventing clumping and allowing for even heat distribution. This results in thoroughly dried laundry without the risk of over-drying or damage to delicate fabrics.

Another significant characteristic of the HBG76 is its user-friendly interface. The dryer is equipped with a programmable control panel that allows operators to set specific drying times and temperatures according to the needs of different fabric types. This flexibility ensures that various laundry loads, ranging from heavy towels to delicate garments, can be processed with precision.

A crucial aspect of the HBG76 is its commitment to energy efficiency. With energy-saving features and options for environmentally friendly operation, the dryer is designed to reduce utility costs while still delivering high-performance results. This not only benefits the environment but also enhances the bottom line for commercial laundry providers.

In conclusion, the American Dryer Corp HBG76 stands out in the competitive landscape of commercial dryers. Its combination of durable construction, innovative drying technologies, user-friendly controls, and energy-efficient features make it a smart choice for any laundry operation looking to improve efficiency and effectiveness. With the HBG76, operators can expect reliable performance and excellent results, all while being mindful of operating costs and environmental impact.