3. Route the power cord (pigtail) or cable conductors through |
|
|
|
the strain relief clamp. |
| FIG. #2 - 4 WIRE | |
|
| TERMINALBLOCK |
|
,_ CAUTION - The conductors should not extend into | I |
|
|
connections. | J | (BLACK) | GREEN |
the dryer more than necessary to make the electrical | LINEt | _/IRE | |
|
|
| |
4. Refer to the Typical Electrical connections listed below |
|
| |
and make the electrical connections as instructed. We |
|
|
|
recommend that a qualifiedservice technician or electri- | NEUTRAL | GROUND | |
clan be consulted before connectingthe dryer. |
| (WHITE) | SCREW |
NOTE: DO NOT REMOVETHE INTERNAL GROUNDWlRE |
|
|
|
OR BRASS STRAP EXCEPT WHERE INSTRUCTED AND |
|
|
|
REQUIRED BY LOCAL CODES AND ORDINANCES OF |
|
|
|
YOUR AREA. |
| LINE2 |
|
|
| (RED) |
|
5. Check to be certain all conductors are correctly installed. |
|
| |
Then securely tighten all terminal nuts and the ground |
|
|
|
screw. |
|
|
|
6. Tighten the strain relief clamp. |
|
|
|
7. Replace the supply cord cover plate. |
| FIG. #3 TypicaIlnstallationWith | |
|
| Flexible Power Cord (Pigtail) |
|
8. Complete the dryer installation. |
|
|
|
|
| White | (Neutral) |
|
| k |
|
TYPICAL ELECTRICAL CONNECTIONS
and line 2 terminals of the terminal block as shown in
Black (Line 1) | _ | Red (Line 2) |
Plug - NEMA
Figure #1. |
|
|
|
|
NOTE: Some | power cords are not color |
|
| |
coded. When using this type | of power cord, connect the |
| White(Neutral) | |
center conductor to the Neutral, connect | one of the out- |
|
| |
side conductors to line 1, and connect the other outside |
|
| ||
conductor to line 2. |
|
| Slack (Line 1) | Red (Line 2) |
|
|
|
| Green (Ground) |
|
|
|
| |
METAL CLAD |
| |||
CABLE OR RIGID METAL CONDUIT | - Remove the |
|
internal green ground wire or brass strap from the Neutral terminal and the ground screw. Connect the power cable conductors to the line 1, Neutral, and line 2 terminals as shown in Figure #2.
NOTE; An
or conduit installation.
approved grounding type strain relief clamp connector must be installed for this type of
|
|
| |
or brass strap from the Neutral terminal and the ground |
|
|
|
screw. Connect the power cord green grounding con- |
|
|
|
ductor to the ground screw. Connect the remaining | _ | BEFORE OPERATING | YOUR DRYER READ |
power cord conductors to the line 1, Neutral, and line 2 | ALL | SAFETY PRECAUTIONS | LISTED IN THE |
terminals as shown in Figure #2. | OPERATING INSTRUCTIONS. |
3