Graco 215363, 222791, 207546, 206955 205997 Skin Injection Hazard, Moving Parts Hazard

Page 3

WARNING

SKIN INJECTION HAZARD

Spray from the gun/dispensing valve, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

DFluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgical treatment.

DDo not point the gun/valve at anyone or at any part of the body.

DDo not put your hand or fingers over the spray tip/nozzle.

DDo not stop or deflect leaks with your hand, body, glove or rag.

DDo not “blow back” fluid; this is not an air spray system.

DAlways have the tip guard and the trigger guard on the gun/valve when spraying.

DCheck the gun diffuser operation weekly. Refer to the gun manual.

DBe sure the gun trigger safety operates before spraying.

DLock the gun trigger safety when you stop spraying.

DFollow the Pressure Relief Procedure on page 6 if the spray tip/nozzle clogs and before clean- ing, checking or servicing the equipment.

DTighten all fluid connections before operating the equipment.

DCheck the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.

DUse only Graco approved hoses. Do not remove the spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.

MOVING PARTS HAZARD

Moving parts, such as the air motor piston, can pinch or amputate your fingers.

DKeep clear of all moving parts when starting or operating the pump.

DBefore servicing the equipment, follow the Pressure Relief Procedure on page 6 to prevent the equipment from starting unexpectedly.

307043 3

Image 3
Contents Model 206955, Series K Instructions-Parts ListImportant Safety Instructions For use with Graco fluid handling pumpsSymbols Table of ContentsMoving Parts Hazard Skin Injection HazardToxic Fluid Hazard Fire and Explosion HazardInstallation GroundingTo ground the pump Before You Start Air Motor ServicePressure Relief Procedure DisassemblyMoving Parts Hazard Cutaway View ReassemblyAir Motor Service Model 207546, Series H, Air Motor Assembly PartsHinged Clamp Mounting Sanitary Cylinder Description QtyN11 N30 32 N18 36 Y37 Stanchion Tube Mounting Model 206955, Series K, Air Motor Assembly Includes itemsModel 205997, Series K Air Motor Assembly Model 215363, Series D Air Motor AssemblyModel 222791, Series D Air Motor Assembly Keep these spare parts on hand to reduce down Silencer KIT AccessoriesTie Rod Pumps Technical DataMounting Hole LayoutsGraco Standard Warranty Graco InformationToll Free 612-623-6921 612-378-3505 Fax