Silva SEA DATA user manual 6. C15 Unit for depth Unit M, 7. C16 Adjusting depth 0.00 ADJ

Page 12

Sea Data

 

 

 

 

 

 

 

 

 

 

English

 

 

 

 

 

 

 

 

 

 

 

True distance from sea chart

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Log trip counter distance

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The current calibration value

C

 

 

 

 

 

 

 

New calibration value

N

 

 

 

 

 

 

 

If you suspect that there is water flow, drive the boat in both directions and divide the trip distance by two.

To enter the new calibration value press KEY increase/decrease with UP/DOWN, move to the next figure with MODE and confirm with KEY.

4.2.6.C15 Unit for depth (Unit M)

The unit for depth is selectable between metres (M), feet (FT) or fathoms

(FA). To change unit press KEY and select unit with UP or DOWN and

confirm with KEY.

4.2.7.C16 Adjusting depth (0.00 ADJ)

It is possible to adjust the depth reading plus/minus 99.9 m. This feature makes it possible to get the reading from either the keel or the water surface.

Example: Your boat has a draft of two metres and the transducer is mounted one half metre below the water surface.

1.If you want the reading from the water surface you have to add 0.5 m

2.If you want the reading from the keel you have to subtract 1.5 m

Note! Calibration should be carried out in the same unit chosen for dis- play.

4.2.8. C17 Unit for temperature (Unit °C)

The unit for temperature is selectable between Celsius (°C) or Fahrenheit (°F). To change unit press KEY and select unit with UP or DOWN and confirm with

KEY.

4.2.9. C18 Temperature adjustment (0°C TMP)

The temperature reading can be adjusted for accurate reading plus/minus nine

degrees.

4.2.10.C19 Unit for trip and total distance (Unit NM)

The unit for distance is selectable between Nautical Miles (NM), Kilome- tres

(KM) and Miles (MI). To change unit press KEY and select unit with UP or DOWN and confirm with KEY.

11

Image 12
Contents Sea Data Sea Data English Edition May Installation IntroductionInstallation SpecificationsPart specifications Installation includes 6 major stepsInstalling the instrument Installing transducerFew do not’s you should consider Transducer must always remain submerged in the waterElectrical installation Log transducer and power supplyPower supply Function overview Log functions IlluminationShallow alarm Deep alarmSilencing an alarm Activate / Deactivate an alarmCalibration 7. C16 Adjusting depth 0.00 ADJ 8. C17 Unit for temperature Unit C9. C18 Temperature adjustment 0C TMP 6. C15 Unit for depth Unit MCustomise your display Warranty English Sea Data Sea Data English