Stow manual Stow SDP-2/SDP-3 Basic Engine

Page 14

STOW SDP-2/SDP-3 — BASIC ENGINE

Figure 3. Engine Controls and Components

INITIAL SERVICING

6.

Choke Lever – Used in the starting of a cold engine, or in

The engine (Figure 3) must be checked for proper lubrication and

 

cold weather conditions. The choke enriches the fuel

 

mixture.

filled with fuel prior to operation. Refer to the manufacturers engine

 

7.

Air Cleaner – Prevents dirt and other debris from entering

manual for instructions & details of operation and servicing. The

engine shown above is a HONDA engine, operation for other

 

the fuel system. Remove wing-nut on top of air filter

types of engines may vary somewhat.

 

cannister to gain access to filter element.

1. Fuel Filler Cap – Remove this cap to add unleaded gasoline to the fuel tank. Make sure cap is tightened securely. DO NOT over fill.

DANGER

Adding fuel to the tank should be done only when the engine is stopped and has had an opportunity to cool down. In the event of a fuel spill, DO NOT attempt to start the

engine until the fuel residue has been completely wiped up, and the area surrounding the engine is dry.

2. Throttle Lever – Used to adjust engine RPM speed (lever advanced forward SLOW, lever back toward operator FAST).

3. Engine ON/OFF Switch – ON position permits engine

 

starting, OFF position stops engine operations.

4.

Recoil Starter (pull rope) – Manual-starting method. Pull

 

the starter grip until resistance is felt, then pull briskly and

 

smoothly.

5.

Fuel Valve Lever – OPEN to let fuel flow, CLOSE to stop

 

the flow of fuel.

Operating the engine without an air filter, with a damaged air filter,

NOTE or a filter in need of replacement will allow dirt to enter the engine, causing rapid engine wear.

8. Spark Plug – Provides spark to the ignition system. Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean spark plug once a week.

9. Muffler – Used to reduce noise and emissions.

WARNING

Engine components can generate extreme heat. To prevent burns, DO NOT touch these areas while the engine is running or immediately after operating. NEVER

operate the engine with the muffler removed.

10. Fuel Tank – Holds unleaded gasoline. For additional information refer to engine owner's manual.

PAGE 14 — STOW SDP-2 / SDP-3 DIAPHRAGM PUMP — PARTS MANUAL — REV. #2 (12/16/03)

Image 14
Contents Model SDP-2/SDP-3 Diaphragm Pumps Page Heres HOW to GET Help Stow SDP-2/SDP-3 Table of Contents Parts Ordering Procedures When ordering parts Please supply the following informationStow SDP-2/SDP-3 Specifications PUMP/ENGINE Specifications PumpDimensions Stow SDP-2/SDP-3 Safety Message Alert Symbols Stow SDP-2/SDP-3 Safety Message Alert Symbols Sight and Hearing hazard Equipment Damage MessagesStow SDP-2/SDP-3 Rules for Safe Operation Maintenance Safety Stow SDP-2/SDP-3 Rules for Safe OperationStow SDP-2/SDP-3 General Information Stow SDP-2/SDP-3 Pump Components Stow SDP-2/SDP-3 Basic Engine Stow SDP-2/SDP-3 PRE-INSPECTION Engine Before StartingStow SDP-2/SDP-3 PRE-SETUP Pump Stow SDP-2/SDP-3 PRE-SETUP Pump Stow SDP-2/SDP-3 Initial START-UP Engine Stow SDP-2/SDP-3 Initial START-UP Engine Normal ShutdownPage Stow SDP-2/SDP-3 Maintenance Pump Stow SDP-2/SDP-3 Maintenance Pump Stow SDP-2/SDP-3 Maintenance Engine Engine Maintenance ScheduleStow SDP-2/SDP-3 Maintenance Engine Stow SDP-2/SDP-3 Preparation for Long -TERM Storage Pump StorageStow SDP-2/SDP-3 Troubleshooting Engine Engine TroubleshootingStow SDP-2/SDP-3 Troubleshooting ENGINE/PUMP Engine TroubleshootingStow SDP-2/SDP-3 Explanation of Code in Remarks Column Items Found In the Remarks ColumnStow SDP-2/SDP-3 Suggested Spare Parts Honda GX120K1QX2 EngineStow SDP-2 Waterbox & Groove Assy -INCH Part Name QTY. Remarks Stow SDP-2 Pump Assy -INCH Pump Frame Stow SDP-3 Waterbox & Groove Assy -INCH PLUG, 2 Fill Stow SDP-3 Pump Assy Stow SDP-3 Pump Assy Stow SDP-2/3 AXLE, HANDLE, Engine MTG. and Bumper Assy Wheels SEMI-PNEUMATIC Honda GX120K1QX2 Engine AIR Cleaner Assy Part Name QTY Remarks Honda GX120K1QX2 Engine Camshaft Assy Part Name Honda GX120K1QX2 Engine Carburetor Assy Gasket SET Honda GX120K1QX2 Engine Control Assy ARM, Governor Honda GX120K1QX2 Engine Crankcase Cover Assy GASKET, OIL Filler CAP Honda GX120K1QX2 Engine Crankshaft Assy CRANKSHAFT, H-TYPE Honda GX120K1QX2 Engine Cylinder Barrel Assy WEIGHT, Governor Honda GX120K1QX2 Engine Cylinder Head Assy GUIDE, Valve OS Optional Honda GX120K1QX2 Engine FAN Cover Assy GROMMET, Adjusting Cover Honda GX120K1QX2 Engine Flywheel Assy FAN, Cooling Honda GX120K1QX2 Engine Fueltank Assy RUBBER, Supporter 107MM Honda GX120K1QX2 Engine Ignition Coil Assy Coil ASSEMBLY, Ignition Honda GX120K1QX2 Engine Muffler Assy Muffler Honda GX120K1QX2 Engine Piston Assy PISTON, Standard Honda GX120K1QX2 Engine Recoil Starter Assy REEL, Recoil Starter No Artwork Avalible Honda GX120K1QX2 Engine Gasket KIT Assy06111ZH7405 Honda GX120K1QX2 Engine Labels Assy Emblem Terms and Conditions of Sale Page Stowconstructionequipment Parts Department

SDP-2, SDP-3 specifications

The Stow SDP-3 and SDP-2 are advanced storage and retrieval systems designed to enhance warehouse efficiency and streamline operations. With their state-of-the-art technology and robust features, these systems cater to various industries, from e-commerce to pharmaceuticals, providing reliable handling of goods and optimizing space utilization.

The Stow SDP-3 is equipped with a high-density storage solution that maximizes vertical space, allowing for greater storage capacity within the same footprint compared to traditional shelving units. Its modular design can be easily adapted to changing inventory needs, making it an agile choice for businesses looking to scale operations. The SDP-3 can utilize various storage methods, including FIFO (First In, First Out) and LIFO (Last In, First Out), accommodating diverse product types.

On the other hand, the Stow SDP-2 offers similar benefits but focuses on smaller, less intensive operations. It is designed to be lightweight and easy to assemble, making it suitable for businesses just beginning to automate their logistics processes. The SDP-2 integrates seamlessly with existing warehouse management systems, enabling real-time inventory tracking and management.

Both systems leverage advanced technologies, such as automated guided vehicles (AGVs) and robotics, to enhance the picking and storage process. These technologies reduce manual labor costs and minimize the risk of human error, ensuring a more efficient operation overall. Furthermore, the SDP series features integrated safety systems, ensuring that both equipment and personnel can operate in a secure environment.

Key characteristics of the Stow SDP systems include their design adaptability, durability, and low maintenance needs. They are constructed from high-quality materials, ensuring longevity even in high-traffic environments. The systems also allow for easy customization, enabling users to configure the layout and specific components to fit their unique requirements.

In conclusion, the Stow SDP-3 and SDP-2 stand out as top choices for modern warehouse solutions. Their combination of space efficiency, ease of use, and advanced technologies makes them invaluable for businesses aiming to enhance their operational capabilities while reducing costs. As automated solutions continue to evolve, the SDP series remains at the forefront of warehouse innovation.