Lowrance electronic 000-0124-69 installation instructions General Nmea 2000 Installation Rules

Page 2

Network backbone

Nodes

120 ohm

 

 

 

120 ohm

terminator

Power Node

 

 

terminator

Fuel Flow

Display Unit

Temp Sensor

Display Unit

General NMEA 2000 Installation Rules

Only devices/sensors should be connected to the bottom of a T connector; the connectors at the top of the T connector are only used for extension cables, terminators and other T connectors

Power the Network only once

A terminator must be connected to each end of the network backbone

You can attach an extension cable between a device and the bottom of a T connector, but there should never be more than 18’ (6 meters) of cable between a device and its T connector; likewise, the network

— including drop lengths — should never be more than 200’ (60 meters) long

Powering a NMEA 2000 Network

If you have an HDS unit, you MUST power the network with a power node.

If you have a LCX or LMS display unit, you can power the network with a power node or with your display unit. It is very important to use only one of these methods for powering your network.

Refer to your unit’s operation manual to power the network with your display unit.

Image 2
Contents Network Construction HDS UnitsInline Terminator Cable General Nmea 2000 Installation Rules Powering a Nmea 2000 NetworkTo install a power node Adding Devices, a Network Node or Extension CableSmall boat example CompatibilityLarge boat example Lower Helm SternBlank Blank How to Obtain Service… For Lowrance 800-324-1356. For Eagle