TRANSDUCER PIVOT ASSEMBLY Assemble the pivot to the transducer main body using the two 1/4x%" alien head screws, two %," tooth washers and two'/," square nuts. Make sure the tooth washers are sandwiched between the transducer main body and the pivot. (See Figure 7). The square nuts are trapped inside the pivot and will not rotate as the alien head screws an; tightened. HOWEVER, DO NOT TIGHTEN AT THIS POINT (See Figure 7).
CAUTION: DO NOT APPLY LOCTITE® OR SIMILAR LOCKING COMPOUNDS BECAUSE THEY WILL ATTACK THE PLASTIC.
Step 4
TRANSDUCER ASSEMBLY
Step 5
ANGLE ALIGNMENT - Set the transducer angle so that it is parallel with the bottom of the boat hull. (See figure 9). Once proper alignment is achieved, tighten the two alien head screws using the %2" alien wrench provided. The screws are visible through the access holes on each side of the metal bracket. Check to be sure the transducer main body is rigidly fastened to the pivot.
Step 6
CHECK POSITION OF TRANSDUCER At this point, check to see that the bottom of the transducer is a minimum of %," below the bottom of the transom.
(However, as noted in STEP 2, the top of the transducer cannot fall below the bottom of the transom). If it is not, remove the transducer assembly from the metal bracket by removing the pin installed during STEP 3. (See Figure 8). Loosen the metal bracket mounting screws, reposition the bracket utilizing it's slotted holes, tighten and reassemble. It may be necessary to replace the silicone sealant after this adjustment is made.