Humminbird TCR ID-10 manual

Page 18

The following describes the functions and how to use them, in order of appearance after you turn the unit on.

1.Sensitivity

Automatic setting: on, "O" or normal

As conditions change, the computer will automatically increase or decrease the sensitivity setting. You can manually increase or decrease the automatic setting from a range of "+5" to "-5." This level will maintain itself as long as you have the unit on, automatically, as a result of the TCR's Sensitivity Bias feature. For example, if you set the sensitivity at "+2," the sensitivity will remain 2 settings higher than the normal automatic settings until you turn the TCR off.

2.Bottom Alarm Automatic setting: off

Use the On/Off button to activate the alarm, and the alarm cursor appears on the screen. Then use the arrow keys to adjust the depth at which the alarm will sound. You'll hear a continuous chirping sound when the bottom is within the area that you've defined with the alarm cursor. This is a great feature to use to alert you to shallow water, or to maintain your position over structure.

3.Fish Alarm Automatic setting: off

The fish alarm is easily activated by pressing the On/Off

button. This 2-level alarm can be set to sound for all fish, or to ignore weaker signals and alarm only for stronger signals, such as those from larger fish. You can also adjust the volume of the fish alarm.

The controls for this function are a little different. Pressing the Up arrow lets you switch between alarms for all fish and large fish. The Down arrow controls volume of the alarm.

Once the instructions have disappeared from the screen, it's easy to tell which alarm you have activated-the alarm for all fish shows both small and large fish symbols at the bottom of the screen, while the "large only" alarm displays only a large fish symbol.

4.Zoom

Automatic setting: off

When zoom is activated by pressing On/Off, it creates a "window" of expanded, up-close information. This window is marked by a cursor at the right of the screen and can be moved up or down with the arrow buttons. The exact depths of the upper and lower limits of the window are displayed as depth scales while you are in zoom.

The size of the zoom window changes as the depth range changes. The window displays 71/2 feet of upclose readings in the 15' and 30' scales, and 15 feet in the 60' and 120' and 30 feet in the 180', 240', 360' and 480' scales. Keep in mind that, using your arrow

Image 18
Contents Page Transducer Mounting Procedure Transducer Mounting OptionsTransom Mounting Procedure Page Page Page Inside Hull Mounting Procedure Installing the LCR Page Installing the Cables Other Mounting OptionsPage Page Testing the Installation BUILT-IN SimulatorReading the TCR ID-10 Screen Page Page Operating the TCR ID-10