Invacare MA60 Specifications, Features, User-Friendly Control Unit, Degree Hose Quick-Connect

Page 2

Invacare® microAIR® MA60 & MA65 Alternating Pressure Mattresses

Body Interface Pressure Imaging Test

 

100

 

95

 

90

 

85

 

80

 

75

 

70

 

65

 

60

 

55

 

50

 

45

 

40

 

35

 

30

 

25

 

20

 

15

MA65

10

0

 

5

Test demonstrates contact measurement between key pressure points. Subject is 5'5" female, 110 lbs Simulation. Individual resident results will vary.

User-Friendly Control Unit

Lightweight unit with LED display and up down arrows for easy adjustment of comfort and therapy settings

90 degree Hose Quick-Connect

Simplifies set-up with one motion

Quick-Connect Air Cells Quick-connect air cells allow easy replacement of individual cells

if necessary

On-Demand

Low Air Loss

When activated at the push of a button, air is released inside the MA65 mattress to keep the mattress cooler and dryer for the resident

Specifications

Resident Risk Level : Medium-High

Cover : Dual-layered, quilted, anti-microbial, fluid resistant vapor-permeable cover protects internal cells. Bottom cover is1000 Denier nylon

Limited Warranty :

1 year on mattress,

2 years on power unit

Power Unit : 50 LPM

Internal cells : 70 Denier urethane coated nylon

Features

Efficient real-time monitoring for correct pressure relief

2” safety foam base adds safety and comfort

CPR release built into mattress

Built-in carrying straps for easy transportation

50 LPM compressor quickly inflates mattress

Power outage safety with mattress hose is connected to the compressor

Settings retained during a power outage will resume

once power is restored

Manual fowler to prevent accidental bottoming out

Energy-saving compressor turns “off” when not needed during pressure maintenance modes

MA65 includes on-demand low air loss

Bariatric

 

MA60

MA65

MA65B42

MA65B48

Width

36"

36"

42"

48"

Depth

10"

10"

10"

10"

Weight Capacity

350 lbs.

350 lbs

1,000 lbs

1,000 lbs

Available with Raised Side Rails (RSR)

*

*

n/a

n/a

Invacare Continuing Care, Inc.

USA

Canada

One Invacare Way

994 Hargrieve Road

Elyria, Ohio 44035

London, Ontario

USA

N6E 1P5 Canada

800-668-2337

800-668-2337

www.invacare-ccg.com info_iccg@ invacare.com

For more information, contact your Invacare Continuing Care Sales Representative at 1.800.668.2337 or visit www.invacare-ccg.com.

© 2009 Invacare Continuing Care, Inc. All rights reserved. Trademarks are identified by the symbols ™ and ®. All trademarks are owned by or licensed to Invacare Corporation unless otherwise noted. Specifications are subject to change without notification.

Form 08.67.9/09

Image 2
Contents Page User-Friendly Control Unit SpecificationsFeatures Degree Hose Quick-Connect
Related manuals