Fluke 724 user manual Limited Warranty & Limitation of Liability

Page 2

LIMITED WARRANTY & LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is three years and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke’s opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption.

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country.

Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

Fluke Corporation

Fluke Europe B.V.

P.O. Box 9090

P.O. Box 1186

Everett, WA 98206-9090

5602 BD Eindhoven

U.S.A.

The Netherlands

11/99

Image 2
Contents 724 Limited Warranty & Limitation of Liability Table of Contents 724 Temperature Calibrator 724 List of Tables 724 List of Figures Viii Introduction Contacting Fluke724 Standard Equipment Safety Information Product Overview Manual724 Safety Information Standard Equipment International Symbols Getting Acquainted with the Calibrator Input and Output TerminalsName Keys Shows the calibrator keys and explains their useB V C a D K E C F F G D H G XW YZ O S S R Display Shows the elements of a typical displayShut Down Mode Getting StartedVoltage-to-Voltage Test Contrast Adjustment Adjusting the ContrastMeasuring Electrical Parameters Upper Display Using Measure ModeCurrent Measurement with Loop Power Connections for Supplying Loop Power Measuring Electrical Parameters Lower Display Measuring Electrical ParametersMeasuring Temperature Using ThermocouplesAnsi IEC Maximum to Using Resistance-Temperature Detectors RTDs RTD Types Accepted RTD Using Source Mode Sourcing Electrical ParametersSimulating Thermocouples Simulating RTDsConnections for Simulating a Thermocouple Connections for Simulating 3-Wire RTD Manually Stepping the Output Setting 0 % and 100 % Output ParametersStepping and Ramping the Output Storing and Recalling Setups Auto Ramping the OutputCalibrating a Transmitter Calibrating a Thermocouple Transmitter Testing an Output Device Calibrating a Chart RecorderReplacing the Batteries Replacing the FuseService Center Calibration or Repair MaintenanceCleaning the Calibrator Replacement Parts MaintenanceZi46f.eps DC mA Measurement SpecificationsDC Voltage Measurement DC Voltage Source Ohms Measurement Ohms Source Temperature, Thermocouples Millivolt Measurement and SourceTemperature, RTD Ranges, and Accuracies ITS-90 Loop Power Supply General Specifications724 Index Recalling, 31 storing, 31 Thermocouple

724 specifications

The Fluke 724 is a cutting-edge temperature calibrator designed to provide precision measurement and calibration for a variety of applications. As part of Fluke's renowned line of calibration tools, the 724 combines advanced technology, ease of use, and robust performance, making it an essential device for professionals in the fields of HVAC, manufacturing, and laboratory environments.

One of the main features of the Fluke 724 is its dual temperature measurement capability. It can measure and source temperature simultaneously, which is particularly useful for professionals who require precise calibration of temperature sensors. This dual functionality enhances efficiency, allowing technicians to perform tasks quickly and accurately without needing multiple devices.

The Fluke 724 supports both thermocouples and RTDs (Resistance Temperature Detectors), and it is compatible with various temperature ranges. This versatility ensures that the device can be employed across different industries and applications, making it a valuable asset in any technician's toolkit. Moreover, its wide temperature range—from -200°C to 1200°C—enables users to calibrate a broad spectrum of temperature instruments.

Another standout technology in the Fluke 724 is its intuitive user interface, featuring a large, easy-to-read display that provides clear measurements and calibration data. The device is designed for user-friendliness, with straightforward navigation that allows users to set up and execute tests quickly. Additionally, the integrated loop powering capability enables the calibration of transmitters without the need for an external power source, making it particularly convenient in field applications.

The robust construction of the Fluke 724 ensures its reliability in challenging environments. It is built to withstand the rigors of daily use, with a rugged case designed to resist impact and environmental factors, making it an ideal choice for both fieldwork and lab settings.

Finally, the Fluke 724 offers a comprehensive set of features including data logging capabilities, which allow users to record and store measurement data for future analysis. This functionality not only enhances accuracy but also provides crucial documentation for regulatory compliance purposes.

In summary, the Fluke 724 temperature calibrator stands out as a versatile, user-friendly, and durable device that meets the rigorous demands of various industries. Its dual measurement capabilities, broad temperature range, and robust design make it an indispensable tool for professionals seeking reliable and accurate temperature calibration solutions.