Radio Shack Marine Instruments Using the Multimeter, Zero Adjustment, Making Measurements

Page 10

3.Use the screw to secure the ammeter to the multimeter, then put the top cover you removed in Step 1 in a safe place.

ZERO ADJUSTMENT

If the needle does not normally rest exactly over 0 on the left side of the ACVA/DCVA scale, use a flat screw- driver to adjust the plastic screw on the center of the multimeter’s face to set the needle to 0.

OHMS

ˆUsing the Multimeter

WARNING: DO NOT TRY TO MEA- SURE ANY VOLTAGE GREATER THAN 500 VOLTS DC/500 VOLTS RMS AC.

Caution: When the multimeter is not in use, always leave the function se- lector set to OFF.

To use the multimeter, use the func- tion selector to switch between the multimeter’s functions. Then connect the test leads to the circuit you want to measure.

MAKING

MEASUREMENTS

For the most accurate readings, the temperature should be between 43°F and 74°F (6°C and 23°C), with a max- imum of 80% relative humidity.

Keep the multimeter lying flat on a non-metallic surface. Also, use a range setting that results in a reading in the upper third of the multimeter’s scale.

For exact readings, look at the scale from an angle where the needle and its reflection in the mirror come to- gether.

Caution: Be sure to select the correct function before you touch the test leads to the circuit or component to be tested.

10

Using the Multimeter

Image 10
Contents Clamp-On AC Ammeter Contents Features Detachable Clamp-On AC AmmeterWord about Safety Special Panel Markings 500V RMS MAXAccuracy SpecificationsRanges MiscellaneousQuick Look at Your Multimeter Installing a Battery PreparationConnecting the Test Leads Connecting the AC Ammeter to the MultimeterZero Adjustment Using the MultimeterMaking Measurements Measuring DC/AC Voltage Measuring Three-Phase AC Voltage Measuring Current Measuring AC Voltage Riding on a DC Source BiasMeasuring AC Current in a Wire Ohms Measuring Wattage Measuring ResistanceCleaning CareReplacing the Fuse Page RadioShack Corporation Fort Worth, Texas