SECTION THREE — Installing the 491
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
961/962 P1 Connector Plug
(Wiring Side View)
Green
Orange |
|
White |
|
Violet | Data Cable |
Brown
Black
Blue
Red (not connected)
FIGURE 8: Interface cable connection from 961/962 to 491
Table 4: Cable connection between the 961/962 and 491
961/962 pin number | 961/962 P1 signal name | Cable wire color | |
9 | Port 3 In (A) | Blue | |
|
|
|
|
10 | Port 3 | In (B) | Black |
|
|
| |
11 | Ground | Brown | |
|
|
|
|
12* | Port 3 | Out (A) | Violet |
|
|
|
|
12* | Port 3 | Out (A) | White |
|
|
|
|
13 | Port 3 | Out (B) | Orange |
|
|
| |
16 | Ground | Green | |
|
|
| |
** | Not connected | Red | |
|
|
|
|
* Connector P1, pin 12 on the 961/962 requires two connections from the cable.
**The red wire is not connected on the 961/962 end, and should be insulated and capped.
PAGE 16 | 491 INSTALLATION MANUAL Revision A |