Stearns Safety & Survival 24MSPT-1 manual Disassembly, Rearming

Page 16

Halkey-Roberts V86160 Manual Inflator ReArming/Status Indicator Instructions

CO2 Cylinder

Step 2

Sensor Ring

Step 3

Bayonet

Tabs

Step 4

Service Indicator

Step 5

Note: Right and Left hand models pictured above. Your inflator will look like either the left or right image.

DISASSEMBLY

(see figure)

Step 1: Unpack or open the life vest so that the manual inflator is visible.

Step 2: Remove gas CO2 cylinder by rotating cylinder counterclockwise then pull out. Discard cylinder.

REARMING

Note: Rearming must follow the sequence below.

Step 3: Check the new cylinder to be sure it has sensor ring attached.

Step 4: Install new cylinder by engaging bayonet tabs in housing, pushing in then turning clockwise 1/8 turn to a full stop.

WARNING: PFD WILL ONLY INFLATE IF

CYLINDER IS TURNED TO FULL STOP.

Step 5: Check to be sure service indicator is green.

Service Indicator

If green, unit is operable.

If red, stop and service unit.

16

print run id

 

Image 16
Contents Do not Remove Prior to Sale Page Specifications Donning InstructionsInspecting Your PFD For Damage Read below for More Detailed InformationInflated Donning Instructions Rearming and Indicator Check InstructionsInflation Instructions Other Inflation Precautions Deflation InstructionsCare and Cleaning Instructions Other USE GuidelinesInspection StorageIV. is Your PFD in Good and Serviceable CONDITION? VI. HOW and WHY to Test Your PFD?HOW do YOU Test Your PFD Using the Manual INFLATOR? Your fully armed PFD,HOW do YOU Test Your PFD Using the Oral INFLATOR? VII. Wear Your PFDVIII. Hypothermia HOW Hypothermia Affects Most AdultsSome Points to Remember About Hypothermia Protection Additional Information Do not Attach PFD’S to Your BoatCO2 Permeation Loss Buddy Line InformationOral Tube Access Tab Disassembly Rearming