Desa VSLR18, VVSA24M, VVDA24M, VVDA18M, VVDA30M Installing Damper Clamp, Connecting to GAS Supply

Page 5

INSTALLATION

Installing Damper Clamp

5

INSTALLATION

Continued

INSTALLING DAMPER CLAMP

Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 3. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed.

Damper Clamp

Damper

Damper

Installation must include an equipment shutoff valve with "T" style handle, gas union and, for propane/LP gas only, a plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 4).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Masonry Fireplace

Manufactured

 

Fireplace

Damper

Clamp

Damper

Figure 3 - Attaching Damper Clamp

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must con- nect log set to gas supply. Follow all local codes.

Installation Items Needed

Before installing log set, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve

test gauge connection

adjustable (crescent) wrench or pliers

sediment trap

tee joint

pipe wrench

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diam- eter or greater to allow proper gas volume to log set. If pipe is too small, undue loss of volume will occur.

We recommend that you install sediment trap in supply line as shown in Figure 4. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed wrong, log set may not run properly.

Approved Flexible Gas Hose (no longer than 36" if required by local codes)

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

 

From Gas Meter

3" Minimum

(5" W.C.** to

10.5" W.C.

 

 

Pressure)

Cap Pipe Nipple Tee Joint

Sediment Trap

Figure 4 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 26.

**Minimum inlet pressure for purpose of input adjustment.

For more information, visit www.desatech.com

901268-01D

Image 5
Contents What to do if YOU Smell GAS GAS LOG Vented Decorative ApplianceSafety Information Table of ContentsON/OFF Safety VALVE/PILOT Product FeatureLocal Codes Product IdentificationFlue Opening Specifications InstallationVenting Specifications for Installation Check GAS TypeConnecting to GAS Supply Installing Damper ClampChecking GAS Connections Hearth PAN InstallationRemoving/Installing Cover, Control Knob, Adding PAN Material Testing Burner for LeaksInstalling the Grate and Logs Curing Logs Lighting Instructions For Your Safety Read Before LightingOperating Appliance Pilot Assembly Cleaning MaintenanceInspecting Burners To Turn OFF GAS to ApplianceObserved Problem Possible Cause Remedy TroubleshootingBe caused by one or both of the following Remedy Observed Problem Possible CauseVVSA18M, VVSA24M, VVDA18M VVDA24M and VVDA30M Illustrated Parts BreakdownParts List Illustrated Parts BREAK- Down Parts List Models FVSA18M FVSA24M, FVDA18M FVDA24M and FVDA30M Parts Available not Shown Manchester Split Oak Logs Arlington Round Oak Logs Parts List Models CVDA18M, CVDA24M and CVDA30M KEY Part Number for CVDA18M CVDA24M CVDA30M Description QTY Series CvsaModels CVSA18M, CVSA24M CPVSA18M and CPVSA24M Cpvsa Series CVSA18M, CVSA24M, CPVSA18M and CPVSA24M Accessories Replacement PartsOwners Registration Form Postage Required 901268-01D Limited Warranty Vented GAS Logs Warranty Information
Related manuals
Manual 28 pages 39.74 Kb

FVSA24M, VSLR18, FVDA18M, VSLR24, FVDA24M specifications

Desa VVSA24M, VVSA18M, VVDA18M, VVDA24M, and VVDA30M are advanced heating solutions that combine efficiency, versatility, and user-friendly features. These models are popular among consumers looking for reliable heating systems for their homes or businesses.

The Desa VVSA series, which includes the VVSA24M and VVSA18M models, is designed for high-performance utilization, making them ideal for medium to large spaces. These units utilize advanced radiant heating technology, which effectively warms up a room by emitting infrared heat, making them energy-efficient and environmentally friendly. The VVSA24M model offers a higher heat output, catering to larger areas, while the VVSA18M is suitable for smaller spaces, providing ample warmth without the added bulk.

On the other hand, the Desa VVDA series comprises the VVDA18M, VVDA24M, and VVDA30M models. This series is notable for its dual-fuel capability, allowing users to choose between propane and natural gas for fuel, enhancing flexibility depending on availability and cost. The VVDA variances cater to different heating needs, with the VVDA30M boasting the highest output, making it perfect for extensive commercial settings or sizable residential spaces. The VVDA18M and VVDA24M serve as excellent alternatives for smaller establishments, maintaining efficient heating performance while reducing energy consumption.

One of the standout features across all these models is the integrated electronic ignition system, which ensures a reliable start and enhances safety by eliminating the need for a continuous pilot light. Additionally, these units are equipped with advanced thermostat controls, allowing users to set their desired temperature accurately and maintain a consistent level of comfort throughout the space.

These Desa models also feature durable construction with high-quality materials, ensuring longevity and resistance to wear and tear. Their sleek designs mean they can fit seamlessly into various interior decors, making them not just functional but also aesthetically pleasing.

In summary, Desa VVSA24M, VVSA18M, VVDA18M, VVDA24M, and VVDA30M encompass a range of heating solutions that cater to diverse needs and preferences. With their innovative technologies, user-friendly features, and robustness, these units exemplify what modern heating systems should offer. They are not just about warmth; they bring comfort, efficiency, and flexibility to any space.