Eagle Electronics Accura 240 Unit won’t turn on, Unit freezes, locks up, or operates erratically

Page 28

TROUBLESHOOTING

If your unit is not working, or if you need technical help, please use the following troubleshooting section before contacting the factory customer service department. It may save you the trouble of returning your unit.

Unit won’t turn on:

1.Check the power cable’s connection at the unit. Also check the wiring.

2.Make certain the power cable is wired properly. The red wire connects to the positive battery terminal, black to negative or ground.

3.Check the fuse.

4.Measure the battery voltage at the unit’s power connector. It should be at least 11 volts. If it isn’t, the wiring to the unit is defective, the battery terminals or wiring on the terminals are corroded, or the battery needs charging.

Unit freezes, locks up, or operates erratically:

1.Electrical noise from the boat’s motor, trolling motor, or an accessory may be interfering with the sonar unit. Rerouting the power and transducer cables away from other electrical wiring on the boat may help. Route the sonar unit’s power cable directly to the battery instead of through a fuse block or ignition switch

2.Inspect the transducer cable for breaks, cuts, or pinched wires.

3.Check both the transducer and power connectors. Make certain both are securely plugged in to the unit.

Weak bottom echo, digital readings erratic, or no fish signals:

1.Make certain transducer is pointing straight down. Clean the face of the transducer. Oil, dirt, and fuel can cause a film to form on the transducer, reducing its effectiveness. If the transducer is mounted inside the hull, be sure it is shooting through only one layer of fiberglass and that it is securely bonded to the hull. Do NOT use RTV silicone rubber adhesive or Marinetex

2.Electrical noise from the boat’s motor can interfere with the sonar. This causes the sonar to automatically increase its Discrimination or noise rejection feature. This can cause the unit to eliminate weaker signals such as fish or even structure from the display.

26

Image 28
Contents Accura Table of Contents Specifications MountingPower Connections SPEED/TEMPERATURE Sensors ST-TBKSensor Chart Three Temperature Sensors Water, T-2, and T-3 Keyboard Menus POWER/LIGHTSModes Split Chart Full ChartFastrak Digital/Chart Window GroupsAutomatic SensitivityRange Automatic Range ManualZoom Automatic Mode ZoomZoom Manual Mode GraylineChart Speed Fish ID FishtrackChart Setup Chart CursorDisplay Zoom BAR Display Zone BARAlarms Depth AlarmsZone Alarm Fish AlarmAdjust Chart Surface Clarity ASP Advanced Signal ProcessingSystem Setup Audio/DisplayReset Distance Log Temperature GraphSystem Information Units of Measure Simulator Preset Options Keel Offset Calibrate Speed Windows Summary Unit won’t turn on Unit freezes, locks up, or operates erraticallyNo fish arches when the Fish ID feature is off Noise Eagle Electronics Full ONE-YEAR Warranty Page How to Obtain Service How to Obtain Service U.S.A. Only