Black & Decker BC25EB Approximate Charging Times, Troubleshooting, Alternator Check Part

Page 10

1.Make sure the charger is in initiation state with a circulating pattern on the display or in charge OFF mode with “000” on the display. If not, press 2/10/25 AMP button repeatedly until “000” shows on the display.

2.Press the Battery Recondition button to start the process.

3.DES appears on the display for 3 seconds, then it changes to three horizontal moving bars.

4.The process takes 24 hours and stops automatically. The display shows “000” when complete.

Alternator Check

Part 1

No Load (Turn OFF all vehicle’s accessories): The battery must be fully charged before testing the alternator. Run the engine long enough to achieve normal idle speed and verify there is a no-load voltage.

1.Press Alternator Check to start the check.

2.Alternator Good LED will light to indicate the alternator is good, or F07 will display to indicate the alternator is out of typical voltage range.

3.Press Alternator Check again to stop the test.

Part 2

Under Load (Accessories ON): Next, load the alternator by turning on as many accessories as possible (except for A/C and DEFROST)

1.Press Alternator Check to start the check.

2.Alternator Good LED will light to indicate the alternator is good, or F07 will display to indicate the alternator is out of typical voltage range.

3.Press Alternator Check again to stop the test.

If the first alternator check indicates a good alternator and the second indicates the alternator is not good, the problem could stem from: loose fan belts, an intermittent diode failure or possibly bad connections between the battery and alternator and/or ground.

Notes: BATTERY VOLTAGE button is disabled in Alternator Check mode.

F07 may display because someone has added a number of accessory loads on the charging system, thereby increasing current demand from the alternator. MAKE SURE THAT THE ALTERNATOR IS RATED TO SUPPORT THE APPLICATION.

This check may not be accurate for every make, manufacturer and model of vehicle. Check only 12 volt systems.

APPROXIMATE CHARGING TIMES

The Black & Decker ® 25 Amp SmartBattery Charger will automatically adjust the charge rate as the battery becomes charged, and stop when the battery is fully charged. Deep cycle batteries may require longer charging time.

For estimates of the time it takes to charge a battery, refer to the following table.

Percent of charge

 

 

 

 

 

 

in battery

75%

50%

25%

0%

at 2 amp rate

7

HRS

14

HRS

NR*

NR*

at 10 amp rate

1.4

HRS

2.8

HRS

4.2 HRS

5.5 HRS

at 25 amp rate

1

HRS

1.2

HRS

1.7 HRS

2.2 HRS

*NR = Not recommended at 2 amps — use a higher charge rate.

The times shown in the table above are approximate and refer to a 50 Ah automotive battery. For example, a 50 Ah (12 volt) battery is discharged (50%). How long should it be charged at the 10 amp rate? See the chart above under “50%” and “at 10 amp rate.”

In most cases, battery charging times will vary depending on the size, age and condition of the battery. Smaller batteries should be charged at a lower rate (2 amps) and an extra hour added to charge time.

TROUBLESHOOTING

Display Indications/Common Problems/Possible Solutions

No Functions

Check and make sure the charger is plugged into a live 110/120 volt AC outlet.

Follow the steps outlined in the Operating Instructions section.

F01 — Internal Shorted Cell Battery

If the battery being charged has an internal shorted cell, the F01 will show. We recommend taking your battery to a certified automotive service center for evaluation.

9

Image 10
Contents AMP Smart Fully Automatic Battery Charger Save this Manual for Future ReferenceRead ALL Instructions Ampere RatingSafety Guidelines / Definitions Preparing to Charge Locate charger as far away from battery as cables permitCharger Location DC Connection Precautions IntroductionAutomatic Float Charge feature is ideal FeaturesControls and Indicators Battery Voltage lights when battery voltage is displayed Operating InstructionsAutomatic Float Charging Charging the BatteryCharge Rate Selection EqualizingRecondition Mode Remove or disconnect the vehicle’s battery when equalizingEngine Start F01 Internal Shorted Cell Battery TroubleshootingPercent of charge Battery 75% 50% Approximate Charging TimesCare and Maintenance Service InformationSpecifications Full FIVE-YEAR Home USE WarrantyInput