Hitachi SJ100 External dimensions and terminal positions, Inverter S J 1 0 004 007 015 022 040

Page 6

External dimensions and terminal positions

Tec hn ic al S pe ci f ic at ion s

002

004

005

007

011

015

022

055

075

 

NFE

NFE

NFE

NFE

NFE

NFE

NFE

LFR

LFR

Tec hn ic al S pe ci f ic at ion s

004

007

015

022

030

040

055

075

 

HFE

HFE

HFE

HFE

HFE

HFE

HFE

HFE

 

 

005 NFE

 

110

SJ100-

002 NFE/NFU

004 NFE/NFU

 

 

 

011 NFE

 

 

 

004 HFE/HFU

007 NFE/NFU

 

118

SJ100-

 

10

 

(without fan)

015HFE/HFU

022HFE/HFU

118

SJ100-

007HFE/HFU

5

SJ100-

015 NFE/NFU

 

 

168

 

 

 

 

10

 

030 HFE

HFE/HFU

 

 

SJ100-

022 NFE/NFU

037 LFU 040

 

5

 

 

 

 

SJ100- 055 LFU/LFR

055 HFE/HFU/HFR

075 HFE/HFU/HFR

075 LFU/LFR

236

 

 

 

 

7

67

 

120

5

10

 

A B C D

98

130

5

A B C D

98

Air

130

5

A B C Air

140

128

 

180

 

 

5

 

 

 

 

A

B

C D

140

 

 

 

128

 

 

Air

 

 

 

168

180

 

 

5

 

 

 

 

A

B C

Air

182

 

 

 

160

 

 

Air

 

 

 

 

257

 

 

D

7

A B C Air

80

4

7

 

 

L

 

L = 93 (002NF)

2,5

 

 

 

 

 

107 (004/005NF)

 

 

 

110

4

7

 

129

 

 

2,5

 

 

110

4

7

 

156

 

 

Fan

6

 

 

D

 

 

 

 

7

 

 

153

 

 

 

3,5

 

 

 

7

 

 

 

164

 

 

Fan

 

 

 

 

6

 

 

D

 

 

 

 

7

 

 

170

 

 

6

 

 

Fan

 

 

 

Second fan built in with inverters 075LFU/LFR.

 

 

Inverter S J 1 0 0 -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

002

 

004

 

 

 

007

 

015

022

037

 

055

 

075

 

 

 

(200V Series)

 

 

 

 

 

 

 

 

 

 

NFU

 

NFU

 

 

 

NFU

 

NFU

NFU

LFU

 

LFU

LFU

 

Protective structure

(Note 1)

 

 

 

 

 

 

 

 

IP20

 

 

 

 

 

 

 

 

Overvoltage category

 

 

 

 

 

 

 

 

III

 

 

 

 

 

 

 

 

Maximum motor size (4P)

0.2

 

0.4

0.55

 

0.75

1.1

1.5

2.2

3.7

5.5

 

7.5

 

in kW (Note 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum capacity

 

230V

0.6

 

1.0

1.1

 

1.5

1.9

3.1

4.3

6.9

9.1

 

12.2

 

in kVA

 

 

240V

0.6

 

1.0

1.2

 

1.6

2.0

3.3

4.5

7.2

9.1

 

12.2

 

Input supply phase

 

 

 

 

 

 

 

Single / Three phase

 

 

 

Three phase

 

Rated input voltage

 

 

 

 

200VAC -10% ~ 240VAC +5%

50/60Hz +/-5%

 

 

Rated output voltage

 

 

 

 

 

 

 

 

Three phase 200 ~ 240VAC

 

 

 

 

 

 

 

(Note 3)

 

 

 

 

 

 

 

 

 

(Corresponds to input voltage)

 

 

 

 

 

 

Rated input current in A

3.5

 

5.8

 

6.7

 

9.0

11.2

17.5

24.0

 

-

 

-

 

-

 

Single phase (Three phase)

(2.0)

 

(3.4)

 

(3.9)

 

(5.2)

(6.5)

(10.0)

(14.0)

(22.0)

 

 

 

 

 

Rated output current in A

1.4

 

2.6

 

3.0

 

4.0

5.0

8.0

11.0

17.5

 

24.0

 

32.0

 

(Note 4a)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output frequency range

 

 

 

 

 

 

 

0.5 ~ 360 Hz (Note 5)

 

 

 

 

 

 

 

Frequency accuracy

 

 

 

 

Digital command: +/-0.01% of maximum frequency

 

 

(at 25°C +/-10°C)

 

 

 

 

 

 

Analog command: +/-0.1% of maximum frequency

 

 

Frequency setting resolution

Digital setting: 0.1 Hz

Analog setting: max. frequency / 1000

 

Voltage/frequency characterist.

 

 

Constant, reduced or high starting (SLV) torque (Note 8)

 

 

Overload current capacity

 

 

 

150% during 60 seconds (once per 10 minutes)

 

 

Acceleration/deceleration time

 

 

0.1 ~ 3000 s

in selectable linear and non-linear mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(second acceleration/deceleration

usable)

 

 

 

 

 

Starting torque (using SLV)

 

 

 

 

> 200%

 

 

 

 

 

> 180%

 

 

 

Braking

torque

Dynam. braking, feedback

 

 

approx. 100%

 

approx. 70%

approx. 20%

 

approx. 30%

 

to capacitor (Note 6)2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External braking resistor

 

 

 

 

approx. 150%

 

 

approx. 100%

 

approx. 80%

 

DC injection braking

Braking is on at the minimum frequency or less (minimum frequency,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

braking time and braking force can be set)

 

 

 

Frequency

 

Dig. operator

 

 

 

Settings using keys

or potentiometer

 

 

 

setting

 

External

 

 

 

 

 

0-10VDC (input impedance 10k Ohm)

 

 

 

 

 

 

 

 

 

signals

 

 

 

 

 

4-20mA (input impedance 250 Ohm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Potentiometer 1k-2k Ohm, 1W (055 ~ 075LFU/LFR: 2W)

 

 

Inputs

Forward /

 

Dig. operator

 

 

Via keys RUN (for start) and STOP/RESET (for stop)

 

 

Reverse run

 

 

 

 

 

 

 

 

 

(Default setting: forward run)

 

 

 

 

 

 

 

(Start/Stop)

 

Ext. signals

 

 

Intelligent input terminals configurable as FW and RV

 

 

 

Intelligent input terminals

FW: Forward run start/stop

RV: Reverse run start/stop

 

 

programmable as

CF1–CF4: Multistage speed

JG: Jogging command

 

 

 

 

 

 

 

 

 

AT: Analog current input selection 2CH: 2.Accel./decel. time

 

 

 

 

 

 

 

 

FRS: Free run stop

 

EXT: External trip

 

 

 

 

 

 

 

 

 

USP: USP function

 

RS: Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

SFT: Software lock

 

PTC: Thermal protection

 

 

 

 

 

 

 

 

DB: Ext. DB input

 

SET: 2. setting active

 

 

 

 

 

 

 

 

 

UP: Acceleration (Remote)

DWN: Decelerat. (Remote)

 

Outputs

Intelligent output terminals

FA1/FA2: Frequency arrival signal

 

 

 

 

 

 

 

 

programmable as

RUN: Motor running signal

 

OL: Overload signal

 

 

 

 

 

 

 

OD: Deviation signal at PID control

AL: Alarm signal

 

Frequency and current

Connection of external analog meter (0-10VDC, max. 1mA) for

 

 

monitoring

 

 

 

frequency or current;

connection of external digital frequency meter

 

Fault alarm contact

 

 

 

 

 

 

 

On when the inverter trips (1c contact).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alternatively usable as intelligent output terminal

 

 

Other functions

 

 

 

Autotuning,

 

Automatic voltage regulation, retry;

analog gain/vias

 

 

 

 

 

 

 

 

adjustment,

 

frequency jump, upper/lower limiter,

output frequency

 

 

 

 

 

 

 

 

display,

trip history monitoring,

carrier frequency setting, PID

 

 

 

 

 

 

 

 

control,

automatic torque boost,

USP function,

2. Setting function,

 

 

 

 

 

 

 

 

ON/OFF control of cooling fan, and many more

 

 

 

 

 

 

 

Protection functions

 

 

Overcurrent, overvoltage, undervoltage, electronic thermal, temp-

 

 

 

 

 

 

 

 

erature abnormality, ground fault, overload, CT error, BRD error

 

Environmental

Ambient temperature

 

 

 

 

 

 

 

-10 ~ 50°C ( Note 7)

 

 

 

 

 

 

 

Storage temperature and

 

-25 ~ 70°C (during short term transportation period only)

 

 

humidity

 

 

 

 

 

 

 

 

20 ~ 90% RH (no dew condensation)

 

 

 

 

 

Vibration

 

 

 

 

 

 

 

 

Max. 5.9m/s2 (=0.6g) at 10-55Hz

 

 

 

 

 

 

Installation location

 

 

 

1000m or less altitude indoors (IP54 or equivalent)

 

 

External color

 

 

 

 

 

 

 

 

 

 

 

Grey

 

 

 

 

 

 

 

 

Options

 

 

 

 

 

Remote operator, copy unit, cable for digital operator,

 

 

 

 

 

 

 

 

 

 

 

reactor for improving power factor, noise filter, OPE-J

 

 

 

Overall weight (approx.)

0.7

 

 

0.8

 

1.3

2.3

2.8

 

 

5.5

 

5.7

 

Note 1: Protective structure is based upon EN60529. Note 2: The applicable motor is a Hitachi

 

standard four-pole motor. When using another motor, make sure that the rated motor current does

 

Inverter S J 1 0 0 -

 

004

007

015

022

 

040

HFR

HFR

(400V Series)

 

HFU

HFU

HFU

HFU

 

HFU

HFU

HFU

Protective structure

(Note 1)

 

 

 

 

 

 

IP20

 

 

 

Overvoltage category

 

 

 

 

 

 

III

 

 

 

Maximum motor size (4P)

0.4

0.75

 

1.5

 

2.2

3.0

 

4.0

5.5

7.5

in kW (Note 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum capacity

 

460V

1.1

1.9

 

2.9

 

4.2

6.2

 

6.6

9.9

12.2

in kVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input supply phase

 

 

 

 

 

 

 

 

Three Phase

 

 

 

Rated input voltage

 

 

380VAC -10% ~ 460VAC +10%

50/60Hz +/-5%

Rated output voltage

 

 

 

 

 

 

Three Phase 360 ~ 460VAC

 

 

(Note 3)

 

 

 

 

 

 

 

(Corresponds to input voltage)

 

 

Rated input current in A

2.0

3.3

 

5.0

 

7.0

10.0

 

11.0

16.5

20.0

Rated output current in A

1.5

2.5

 

3.8

 

5.5

7.8

 

8.6

13.0

16.0

(Note 4b)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output frequency range

 

 

 

 

 

0.5 ~ 360 Hz (Note 5)

 

 

Frequency accuracy

 

 

 

Digital command: +/-0.01% of maximum frequency

(at 25°C +/-10°C)

 

 

 

 

Analog command: +/-0.1% of maximum frequency

 

Frequency setting resolution

 

 

 

 

 

Digital setting: 0.1 Hz

 

 

 

 

 

 

 

 

 

 

 

Analog setting: max. frequency / 1000

 

Voltage/frequency characterist.

Constant, reduced or high starting (SLV) torque (Note 8)

Overload current capacity

 

150% during 60 seconds (once per 10 minutes)

 

Acceleration/deceleration time

0.1 ~ 3000 s in selectable linear and non-linear mode

 

 

 

 

 

 

 

 

(second acceleration/deceleration usable)

 

Starting torque (using SLV)

 

 

> 200%

 

 

 

 

> 180%

 

Braking

torque

Dynam. braking, feedback

approx. 100%

 

approx.

approx. 20%

approx. 30%

to capacitor (Note 6)

 

 

 

 

 

 

70%

 

 

 

 

 

 

 

External braking resistor

approx. 150%

 

approx. 100%

approx. 80%

 

 

DC injection braking

Braking is on at the minimum frequency or less (minimum frequency,

 

 

 

 

 

 

 

 

braking time and braking force can be set)

 

 

Frequency

Dig. operator

 

Settings using keys

or potentiometer

 

 

setting

External

 

 

 

0-10VDC (input impedance 10k Ohm)

 

 

 

 

signals

 

 

 

4-20mA (input impedance 250 Ohm)

 

 

 

 

 

 

 

Potentiometer 1k-2k Ohm, 1W (055 ~ 075LFU/LFR: 2W)

 

Forward /

Dig. operator

Via keys RUN (for start) and STOP/RESET (for stop)

Inputs

Reverse run

 

 

 

 

 

 

 

(Default setting: forward run)

 

 

(Start/Stop)

Ext. signals

Intelligent input terminals configurable as FW and RV

Intelligent input terminals

FW: Forward run start/stop

RV: Reverse run start/stop

 

programmable as

CF1–CF4: Multistage speed

JG: Jogging command

 

 

 

 

 

 

AT: Analog current input selection 2CH: 2.Accel./decel. time

 

 

 

 

 

 

FRS: Free run stop

 

 

EXT: External trip

 

 

 

 

 

 

 

USP: USP function

 

 

RS: Reset

 

 

 

 

 

 

 

 

SFT: Software lock

 

 

PTC: Thermal protection

 

 

 

 

 

 

DB: Ext. DB input

 

 

SET: 2. setting active

 

 

 

 

 

 

UP: Acceleration (Remote)

DWN: Decelerat. (Remote)

Outputs

Intelligent output terminals

FA1/FA2: Frequency arrival signal

 

 

 

Frequency and current

Connection of external analog meter (0-10VDC, max. 1mA) for

 

programmable as

RUN: Motor running signal

 

 

OL: Overload signal

 

 

 

 

 

 

OD: Deviation signal at PID control

AL: Alarm signal

 

monitoring

 

 

 

frequency or current; connection of external digital frequency meter

Fault alarm contact

 

 

 

 

 

On when the inverter trips (1c contact).

 

 

 

 

 

 

 

 

Alternatively usable as intelligent output terminal

 

Other functions

 

 

 

Autotuning,

Automatic voltage regulation,

retry;

analog gain/vias

 

 

 

 

 

 

adjustment,

frequency jump, upper/lower limiter,

output frequency

 

 

 

 

 

 

display,

trip history monitoring,

carrier frequency setting,

PID

 

 

 

 

 

 

control,

automatic torque boost,

USP function, 2. Setting function,

 

 

 

 

 

 

ON/OFF control of cooling fan, and many more

 

 

Protection functions

 

 

Overcurrent, overvoltage, undervoltage, electronic thermal, temp-

 

 

 

 

 

 

erature abnormality, ground fault, overload, CT error, BRD error

Environmental

Installation location

 

1000m or less altitude indoors (IP54 or equivalent)

 

 

Ambient temperature

 

 

 

 

 

-10 ~ 50°C ( Note 7)

 

 

 

 

Storage temperature and

-25 ~ 70°C (during short term transportation period only)

 

humidity

 

 

 

 

 

 

20 ~ 90% RH (no dew condensation)

 

 

Vibration

 

 

 

 

 

 

 

Max. 5.9m/s2 (=0.6g) at 10-55Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External color

 

 

 

 

 

 

 

 

 

Grey

 

 

 

Options

 

 

 

Remote operator, copy unit, cable for digital operator,

 

 

 

 

 

 

reactor for improving power factor, noise filter, OPE-J

Overall weight (approx.)

1.3

 

 

1.7

 

 

2.8

 

 

5.5

5.7

(Contd. from prev. page) Note 4b: The initial data setting value of 030H is same as 040H. So be

sure to set the values b 12 and b 22 of 030H for the motor. Note 5: Confirm with the motor manu-

Legend:

A Control terminals

B Alarm terminals

 

C Main terminals

D Grounding terminal

(All dimensions are in millimeters)

not exceed the rated inverter current. Note 3: The output voltage will decrease if input voltage

decreases. Note 4a: The initial data setting values of 005N/011N are same as 004N/007N. So be sure

to set the values b 12 and b 22 of 004N/007N for each motor.

(To be continued on next page)

facturer the motors maximum rpm when using a motor running at frequencies higher than 50/60Hz. Note 6: Torque will be reduced when the base frequency exceeds 50Hz. Note 7: In the range of 40 to 50°C reduce carrier frequency 2kHz and derate output current 80%, and remove the top cover.

12

13

14

Image 6
Contents SJ100 Series Table of Contents Trip Contents Display Hitachi Inverter SJ100 SeriesDisplay Function Standard Set Setting Value From previousSafety measures Large areas. ConsequentlyCables. This influence you can minimize 400V Series External dimensions and terminal positionsInverter S J 1 0 004 007 015 022 040 To be on next

SJ100 specifications

The Hitachi SJ100 series represents a significant advancement in the field of variable frequency drives (VFDs), designed to enhance energy efficiency and operational reliability in various industrial applications. Compact in design yet powerful, the SJ100 is tailored for a wide range of tasks, making it a versatile addition to any automation system.

One of the standout features of the SJ100 is its superior control technology, which utilizes advanced vector control methods to ensure optimal motor performance. This allows for precise speed and torque control, leading to enhanced responsiveness and reduced energy consumption. The drive is also capable of handling a diverse array of motor types, including induction and permanent magnet motors, making it suitable for numerous industrial sectors.

The SJ100 incorporates a robust set of built-in features designed to simplify installation and operation. With an easy-to-navigate LCD control panel, users can quickly set parameters and monitor performance. Additionally, the drive includes a variety of communication options, such as Modbus and CANopen, facilitating seamless integration into existing control systems. This adaptability ensures that the SJ100 can be utilized in various setups, from simple single-drive configurations to complex multi-drive systems.

Another notable characteristic of the SJ100 is its energy-saving capabilities. With advanced algorithms and optimized motor control, the drive significantly reduces energy consumption under varying load conditions. This feature not only helps decrease operational costs but also contributes to a more sustainable and environmentally friendly approach to industrial processes.

Moreover, the SJ100 series boasts a high degree of reliability thanks to its robust construction and protective features. It includes integrated protection against over-temperature, over-current, and voltage fluctuations, ensuring the drive operates safely in demanding environments. The SJ100 is also designed with a wide operating temperature range, allowing it to perform reliably in extreme conditions.

Additionally, the drive supports a variety of customizable functions, such as programmable logic, acceleration/deceleration control, and multi-function inputs/outputs. These features empower users to tailor the SJ100 to meet specific application requirements, enhancing productivity and operational efficiency.

In summary, the Hitachi SJ100 series stands out as a cutting-edge solution for industrial automation, combining advanced control technologies, energy efficiency, and robust reliability. Its versatility and user-friendly features make it an exceptional choice for a myriad of applications, reinforcing Hitachi's commitment to innovation in the field of industrial drives.