Mercury Marine 899337001 manual Air Chamber Repair ‑ Hypalon Fabric

Page 32

MAINTENANCE

4.Push in the valve stems on the side air chambers to release the air pressure evenly on all chambers. Push in the valve stem and turn the stem a quarter turn clockwise to lock the valve in the open position.

Air Chamber Repair ‑ Hypalon Fabric

!

WARNING

Avoid serious injury or death from a fire, explosion or poisoning. The glues and solvents used for repairing inflatables are toxic and highly flammable. As a safety precaution, always work outdoors or in an area that is well‑ventilated, and away from any open flames, sparks, or appliances equipped with pilot lights. Breathing the vapors or exposure to the skin may be hazardous to your health. Avoid breathing the vapors and contact with skin and eyes by wearing a carbon filter respirator and protective gear over all exposed areas of the body.

The repair kit which comes with the boat is a one part glue operation and should be used for emergency minor repair. For a permanent repair, a two part Hypalon glue should be used. This two part Hypalon glue and patching materials are available from Mercury Marine.

Small tears and punctures in the air chambers which are 1 cm (0.393 in.) or less, can be repaired in an emergency. Larger areas, or if the patch will overlap a seam, should be patched by a professional repair technician at an inflatable repair station. Contact your local Mercury dealer for the nearest inflatable repair station.

For the best results when gluing, the relative humidity should be less than 60%, ambient air temperature should be between 18 °C to 25 °C (65 °F to 77 °F) and not in direct sunlight.

Cut out a patch large enough to overlap the damaged area by a minimum of 38 mm (1.5 in.) from all sides. Center the patch over the damaged area and with a pencil trace the outline of the patch. Apply masking tape around the perimeter of the outlined patch area to ensure a tight and clean glue line.

28

Image 32
Contents Warranty Message Dynamic 260, 280HIN Table of Contents Towing Air Chamber Deflates Accidently Beaching Warranty Registration United States and Canada Warranty InformationTransfer of Warranty What is Covered Duration of Coverage What Mercury will doHOW to Obtain Warranty Coverage What is not CoveredDisclaimers and Limitations Before Operating Your Boat General InformationBoaters Responsibilities Lanyard Stop Switch General Information Protecting People In The Water While YOU are CruisingWave And Wake Jumping While Boat is StationaryImpact With Underwater Hazards Exhaust Emissions Be Alert to Carbon Monoxide PoisoningGood Ventilation Poor VentilationSafe Boating Suggestions While Boat is MovingSpecifications Description Model Manufacturers Plate Wind Force and Wave HeightPowered Boat Rating Boat Components Components LocationBack View Front ViewTransom View Side ViewTransporting Trailering BoatOperation InflationOutboard Power Lifting the BoatPre‑Operating Check List Drain Valve Operation LoadingBeaching TowingAir Chamber Deflates Accidently Maintenance Cleaning ProcedureDeflating Fabric SurfacesAir Chamber Repair ‑ Hypalon Fabric ONE Part Glue Emergency Repairs only TWO Part AdhesiveAir Chamber Repair ‑ PVC Fabric Maintenance Storage Storage PreparationOwners Service Assistance Service AssistanceParts And Accessories Inquiries Service Away From Home