Pelco L560 installation manual Installation Guidelines

Page 8

Installation Guidelines

A typical installation and connection routine for the L560RC 2/3Kw searchlight is as follows:

Referring to wiring diagram C22978, a supply is fed to the control panel, which then provides a common feed to the motor gearbox and the searchlight.

Cables required to be connected by the customer: -

4 core 1.5mm2 cable from the Motor Gearbox to the Control Panel. 12 core 0.5mm2 cable from the Motor Gearbox to the Control Panel.

(Customer may need to provide a suitable junction box to extend these two cables – 3 metres supplied). The Mains cable to the Control Panel to be supplied by the customer.

The searchlight head is pre-wired along with the connecting cable to the motor gearbox.

Back to Top

Image 8
Contents User Instruction & Installation Manual Contents Introduction Safety Precautions Technical Information Safety Precautions Preparing the Mounting PositionMethod of Electrical Connection Installation Guidelines Operating Instructions When fitting the lamp TestingFailure of Lamp to light RemedyMaintenance and Servicing Wiring Diagram and General Assembly Drawing Number DescriptionPage Page Page Part Number Description