ACR Electronics 2766.6, Y1-03-0167 manual Inspection Check, Periodic Operational Check

Page 11

b.Remove old battery and place new battery in battery clip with groove side of battery down and flat side of battery up. Caution: Make sure flat side of battery is up. Otherwise, the polarity of the battery would be reversed and damage to the battery will occur. The battery also poses a possible fire, explosion, or burn hazard when placed in the battery clip upside down. A semiconductor diode protects the electronics from damage due to battery reversal.

c.Put the battery expiration date on the flat side of the battery and on the EPIRB case with ACR Part No. A1-20-0857 or equivalent permanent shield label.

d.Grease the top cap o-ring with Dow Corning number 4 Silicone Grease, ACR Part No. A2- 09-0069.

e.Replace the four- (4) screws holding the top cap to the bottom case of the Beacon. Make sure screws are tight but do not use excessive torque, which could strip the threads in the top cap.

5.All routine service or battery replacement must be carried out at ACR or by factory authorized personnel at authorized service centers. In addition to replacing the battery, the o-rings will be replaced and the EPIRB will be hydro statically re-certified. Please call ACR for the location of your nearest authorized service center at least 30 days before expiration date.

6.Safety Precautions:

a)Warning: To avoid possible fire, explosion, leakage or burn hazard, do not open, recharge, disassemble, heat above 71°C (160°F) or incinerate.

b)DOT regulations require that minimum packaging standards be met when shipping certain materials. The original shipping container should be retained for this reason. If the original container is lost, please contact ACR Customer Service prior to shipment of unit.

4.3INSPECTION CHECK

The following checks should be made during the periodic servicing:

1.Check the antenna tip and spring for any signs of damage or corrosion. If antenna has been bent during storage, it is normal for it to maintain a slight bend. This will not affect performance.

2.Check the antenna for any signs of chafing, wear, cracks, or other damage, and signs of resultant corrosion beneath the covering.

3.Check the antenna socket at the cap surface for any sign of looseness or corrosion.

4.Check the Beacon housing for signs of damage or mishandling. Dents or damage to the top end could result in an operational malfunction during an emergency.

5.If unit has been submerged or sprayed with salt water, it should be thoroughly rinsed with fresh water. Including extending and collapsing antenna several times while submerged in fresh water to purge any salt water.

4.4PERIODIC OPERATIONAL CHECK

7

Y1-03-0167 Rev. B

Image 11
Contents Product Support Manual Y1-03-0167 Rev. B Foreword ACR Mini B300TM ILS Epirb Table of Contents Mini B300TM ILS H2ON Epirb Satellite Detection AuthorizationsIntroduction General PurposeSatellite Detection CharacteristicsCharacteristics Technical DataDeactivation Installation GeneralOperation General Manual ActivationOperational Notes Maintenance GeneralBattery Check and Service Periodic Operational Check Inspection CheckPackaging and Transportation Testing GeneralOperational Testing Y1-03-0167 Rev. B