Circuit Breakers and Fuses

RESET A CIRCUIT BREAKER

Circuit breakers are self-setting and do not need to be reset manually.

REPLACE A FUSE

Each power supply is provided with extra fuses should one need to be replaced.

NOTE: This power supply does not support hot swapping of fuse(s). Power down the unit before replacing a fuse.

To replace a fuse:

WARNING: To avoid the threat of electric shock, always disconnect the power supply before you replace a fuse. Any other device attached to the power supply will be turned off automatically when the power supply is disconnected.

1.Disconnect the power supply.

2.Locate the fuse that must be replaced on the front of the power supply.

3.Using a flathead screw driver, rotate the fuse holder a quarter turn to the left, and then remove it from the power supply.

4.Remove the damaged fuse from the fuse holder,, and then insert a replacement fuse of the same amperage.

5.Insert the fuse holder back into its slot on the front panel of the power supply, and then rotate the fuse holder a quarter turn to the right to secure it in place.

6.Reconnect the power supply.

16

C607M-E (2/09)

Image 16
Contents RCS Series Rack Mount Power Supply Page Contents List of Illustrations Regulatory Notices Radio and Television InterferenceImportant Safety Instructions Description ModelsParts List Before You BeginIndicators and Connections Front PanelRear Panel Input Output Models 115 VAC 230 VACRack Installation To install the power supplyInserting the Rear Support Rails C607M-E 2/09 Connecting Devices to the Power Supply Recommended Wiring Distances Power ConsumptionCircuit Breakers and Fuses Reset a Circuit BreakerReplace a Fuse Specifications PowerPage Product Warranty and Return Information