Pioneer SE-DIR800C manual Safety Information, For Canadian Model only

Page 2

1

2

3

4

SAFETY INFORMATION

A

This service manual is intended for qualified service technicians; it is not meant for the casual do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual.

Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician.

WARNING

BThis product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to cause cancer, birth defects or other reproductive harm.

Health & Safety Code Section 25249.6 – Proposition 65

NOTICE

(FOR CANADIAN MODEL ONLY)

Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB indicate that replacement parts must be of identical designation.

REMARQUE

(POUR MODÈLE CANADIEN SEULEMENT)

CLes symboles de fusible (fusible de type rapide) et/ou les pièces de remplacement doivent avoir la même désignation.

(fusible de type lent) sur CCI indiquent que

D

E

(FOR USA MODEL ONLY) 1. SAFETY PRECAUTIONS

The following check should be performed for the continued protection of the customer and ser vice technician.

LEAKAGE CURRENT CHECK

Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229 - 2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120V AC 60 Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5 mA.

 

 

 

 

 

 

 

 

 

 

 

Reading should

 

 

 

 

 

 

 

 

Leakage

not be above

 

 

 

 

 

 

 

 

0.5 mA

 

 

 

 

 

 

 

 

current

 

 

 

 

 

Device

 

tester

 

 

 

 

 

under

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test all

 

 

 

 

 

 

 

 

 

 

exposed metal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

surfaces

 

 

 

 

 

 

 

 

Also test with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

plug reversed

 

 

 

 

 

 

 

 

(Using AC adapter

 

 

 

Earth

 

 

 

 

plug as required)

 

 

 

ground

AC Leakage Test

ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURN- ING THE APPLIANCE TO THE CUSTOMER.

2. PRODUCT SAFETY NOTICE

Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement par ts which have these special safety characteristics are identified in this Service Manual.

Electrical components having such features are identified by marking with a on the schematics and on the parts list in this Service Manual.

The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards.

Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER.

F

2

1

2

SE-DIR800C

3

4

Image 2
Contents SE-DIR800C This Manual is Applicable to the Following Models and TypesSafety Information For Canadian Model onlyContents Specifications SpecificationsAccessories Exploded Views and Parts List Packing Parts List Description Mark NoTransmitter Section Transmitter Section Parts List Mark No DescriptionCable wiring Diagram Headphone SectionHeadphone Section Parts List Photo PCB Assy WWX1069 Block Diagram and Schematic DiagramMain PCB Assy WWX1065 Power PCB Assy WWX1066 Photo PCB Assy WWX1068 PCB Assy PCB Assy WWX1067 PCB Connection Diagram Side a Side BPower PCB Assy Side aMain PCB Assy Speaker Side a PCB Assy IC1 IC3 IC5 Side B PCB Assy Side B List of Assemblies PCB Parts ListBpower PCB Assy Amain PCB AssyEpcb Assy CL.PHOTO PCB AssyDR.PHOTO PCB Assy Adjustment General Information Trouble ShootingSymptom No recharging possible Symptom No sound from the cordless headphones POWER-OFF Power on Start Power Board Assy Disassembly TransmitterHeadphones Board Assy Main Board AssyLead dressing on the L-ch side Lead dressing on the R-ch sideList of IC Transmitter TRE-D800YSS932 PCB Assy IC1 Pin Arrangement Top viewBlock Diagram Pin Function Pin Name FunctionOPORT0 RAMA11 LC83200W PCB Assy IC2 I/F Block Pin Name Function CXD4003Q PCB Assy IC3 Block Diagram Daavd TEST32 Bcko Sclk PEF001A9 PCB Assy IC4 Pin Name Pin FunctionHeadphone SE-DHP800 CXA3504M Main PCB Assy IC1 AGC22 Pin Arrangement Top view Block Diagram CX4004R Main PCB Assy IC2Vdde About LOT Mark Indication Indication of lot is four columnsPanel Facilities Controls and displaysTransmitter front Transmitter rear Headphones