Digital Antenna 4KSBR-50U operation manual Marine Installation

Page 11

5. Marine Installation

Review pre-installation considerations and determine site installation plan.

1.Install supplied outside antenna (PN 288-PW) to vertical surface or pole with supplied hardware. Mount the outside antenna clear of metal objects and obstructions and as high as possible. Use PN F114 to mount 288-PW to 1”-14 threaded basse. Outside antenna must be mounted in a vertical position. The 4KSBR-50U system may also be used with one of Digital Antenna’s marine 9dB gain dual band cellular antennas (pg 15). (Follow minimum 40’ inside and outside antenna separation guideline) Antennas must be separated by a structure and a 40’ or greater distance with as much vertical separation as possible. Vertical separation is better than horizontal.

WARNING! - Only Digital Antenna authorized products may be used with the 4KSBR-50U system. Using unauthorized equipment will harm the 4KSBR-50U system, can be detected and voids the warranty.

2.On supplied 50’ cable (PN 340-50NM) (or optional 25’ extension cable or 75’ or 100’ replacement PowerMaxTM cable) attach N male connector to N female connector on outside antenna. Secure cable to the side of the building with appropriate fasteners (not supplied). Route cable according to site installation plan to the DA4000SBR unit.

3.Attach mini-UHF male connector at the end of the supplied 50’ cable to DA4000SBR unit on the port labeled outside antenna. Attach the 6’ cable attached to the inside antenna and stand to the port labeled inside antenna. The inside antenna must be operated in a vertical position. DO NOT turn the repeater on until antennas and cables are securely attached.

4.The DA4000SBR unit has four mounting holes that can be fastened to a secure surface. (fastening hardware not included)

5.When using 110VAC - Plug 100-240VAC power supply to the DA4000SBR unit. Plug the other end into standard 110VAC receptacle.

When using 12VDC – Plug the 12 VDC to 5 VDC power cable (PN DP515) into the DA4000SBR unit. Plug the other end into a 12VDC cigarette style power source.

The 12 VDC power supply, PN DP515, has a micro-processor controller to turn the repeater off if not properly installed. If a red flashing light appears on the power supply, relocate the inside and outside antennas until the power supply has a constant green light. The power supply can be reset by unplugging the cigarette adapter from the power source.

WARNING!

To have DC power hardwired consult a professional electronic technician.

6.Turn the power switch to ON. If the light on the DA4000SBR unit is green and the coverage area is greater than 1-2’ then the 4KSBR-50U system is operating. Test the amplifier/repeater system by making a cell call and verifying that the indicator light does not turn red. If the light on the DA4000SBR unit is red immediately turn OFF the DA4000SBR unit and refer to the Amplifier/Repeater status section.

11

Image 11
Contents PowerMaxTM 4KSBR-50U Page Read instructions completely before attempting install FCC Regulations Limitation on LiabilityInstallation Procedure Installation ToolsElectrical Power LED AMPLIFIER/REPEATER StatusInterior Coverage Problems Coaxial Cable Recommendations Inside Coverage area is based upon outside signal strength Home/Office InstallationMarine Installation RV Installation Inside Antenna PN 135-RD SpecificationsAmplifier/Repeater Unit PN DA4000SBR Outside Antenna PN 288-PWPower Cable PN DP515 Power Supply PN DP255Omni-directional Cell Antennas Outside Antenna & Accessory OptionsTechnical Support