Shure 565SD specifications General, Features, Model Variations, Connections, Impedance Selection

Page 1

Model 565SD User Guide

4.Reassemble plug element into microphone and seal setscrew securely by turning out (clockwise).

SET SCREW

PLUG

ELEMENT

IMPEDANCE

PIN 3

GENERAL

The UNISPHERE I 565 Series microphones are dual-imped- ance, unidirectional dynamic microphones with a strong, wire-mesh, spherical front grille that contains a highly effective wind and “pop“ filter.

Shipped connected for low-impedance operation, 565 Series microphones provide excellent vocal or speech reproduction on lecterns and stages, and are a popular choice for use in public au- ditoriums, churches, convention halls, and schools.

FEATURES

Selectable dual impedance operation

Silent magnetic reed on/off switch with lock-on option

Cardioid dynamic

Frequency response: 50 to 15,000 Hz

MODEL VARIATIONS

Model 565SD-CN:Supplied with 6.1 m (20 ft) XLR cable.

Model 565SD-LC:No cable supplied.

CONNECTIONS

When using the microphone with a balanced input, pins 2 and 3 are the audio signal carriers. When using the microphone with an unbalanced input, use a cable wired with pin 2 as the signal carrier and pin 3 connected to the cable shield (ground), such as the Shure C20HZ high-impedance cable.

IMPEDANCE SELECTION

The microphone is shipped connected for low impedance oper- ation. To change to high impedance, proceed as follows (refer to Figure 1):

1.Remove plug element at receptacle end of microphone by turning slotted setscrew in (counterclockwise) and carefully withdrawing plug element from case.

2.Disconnect 2-terminal impedance selection socket from rear of plug element.

3.Reconnect 2-terminal impedance selection socket in reverse position so that pin 3 of plug element is inserted in socket ter- minal “H” (White).

©2005, Shure Incorporated 27C3060 (Rev. 7)

SELECTION SOCKET

IMPEDANCE SELECTION-

RECEPTACLE END OF MICROPHONE

FIGURE 1

POLARITY

All cables and microphones should be tested to ensure that they have the same polarity. To test two microphones and/or their ca- bles for proper polarity, connect them to an amplifier and talk or sing into them while holding them three or four inches apart. The sound from the speakers should be the same when talking into ei- ther microphone or directly between them. If the sound drops dras- tically, or if a dead spot is found when talking between the two microphones, either the microphones or their cables have opposite polarity.

To change the polarity of a microphone cable, either use a Shure A15PRS phase reverser or interchange the wires connected to pins 2 and 3 of the three-pin connector at one end of the cable. To change the polarity of a microphone, the microphone cartridge leads must be interchanged. This should be performed by your dealer, the Shure Factory Service Department, or other qualified service personnel.

SPECIFICATIONS

Type

Dynamic

Frequency Response

50 to 15,000 Hz

 

 

+20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dB

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

3

4 5 6 789

 

2

3

4 5 6 789

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

50

100

 

 

 

 

1000

 

 

 

 

10000

20000

Hz

Printed in U.S.A.

Image 1
Contents Specifications FeaturesGeneral Model VariationsReplacement Parts Furnished AccessoryOptional Accessories CertificationsAvantages GénéralitésVariantes BranchementsAccessoires EN Option Accessoires FournisHomologation Pièces DE RechangeTechnische Eigenschaften AllgemeinesModellvarianten AnschlüsseMitgeliefertes Zubehör ZertifizierungErsatzteile SonderzubehörCaracteristicas GeneralidadesVariedades DE Modelos ConexionesAccesorio Suministrado CertificacionesRepuestos Accesorios OpcionalesCaratteristiche Descrizione GeneraleDescrizione DEI Modelli CollegamentiAccessori Opzionali Accessori in DotazioneCertificazioni Parti DI Ricambio