Installing the VLR 102 Receiver and the VLR 102SR Secondary Receiver

To install the VLR 102 IR Receiver or the VLR 102SR Secondary Receiver in a drop ceiling:

1.In the ceiling tile, cut a hole 2 to 3 inches (50 to 76 m) in diameter.

2.Align the center of the receiver housing with the hole in the ceiling tile.

3.Insert the mounting screw through the receiver housing and the hole in the ceiling tile.

4.Attach the provided Z-bracket to the end of the screw on the back side of the ceiling tile. Replace the ceiling tile.

5.Pull an Ethernet cable to the receiver location, and connect one end of the cable to the RJ-45 jack (labeled OUT) on the receiver base.

6.Align the arrow on the dome tab with the raised arrow on the edge of the housing. Rotate the dome clockwise until the arrow on the tab aligns with the raised dot on the housing.

7.Connect the other end of the Ethernet cable to the PoleVault switcher.

8.If you are connecting a VLR 102SR secondary receiver:

Connect an Ethernet cable to the RJ-45 jack labeled OUT on the secondary receiver and to the RJ-45 jack labeled IN on the VLR 102 Receiver.

4

1

2

6

7 3

5

 

8

 

Out

In

Out

5

VLR 102SR

VLR 102

N15779

 

 

 

1A RGB

2A RGB

3A RGB

4A RGB

I

POWER N

P

U

T

S

12V

1B RGB

2B RGB

3B RGB

4BRGBB

3/VIDEOVIDEO

4/VIDEO

5A MAX

 

 

 

 

 

 

PoleVault Switcher

 

 

 

17TT

 

LINE OUT

AMPLIFIED AUDIO OUT

 

 

 

US

 

 

DO NOT

 

 

 

 

®

AUDIO/VIDEO

 

 

GROUND

 

 

 

 

LISTED

 

APPARATUS

 

 

OR SHORT

 

 

2/4/8

 

 

 

 

 

 

SPEAKER

 

 

Ohms

 

OUTPUTS

 

VOICELIFT

L

R

OUTPUTS

 

 

 

 

 

RECEIVER

CLASS 2 WIRING

L

R

 

RGB

VIDEO

 

 

 

 

L

R

10V

50mA

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

Tx Rx IR

12V

 

 

 

 

AUX AUDIO

PAGING

 

RS-232 MLC/IR

 

 

 

 

 

INPUT 5

SENSOR VOL/MUTE

 

 

7

Extron USA - West

Extron USA - East

Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

 

Headquarters

 

 

 

 

 

 

 

+800.633.9876

+800.633.9876

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

+400.883.1568

+971.4.2991800

 

+81.3.3511.7656 FAX

+971.4.2991880 FAX

 

Inside USA/Canada Only

Inside USA/Canada Only

Inside Europe Only

Inside Asia Only

Inside China Only

 

 

 

 

+1.714.491.1500

+1.919.863.1794

+31.33.453.4040

+65.6383.4400

 

+86.21.3760.1568

 

 

+1.714.491.1517 FAX

+1.919.863.1797 FAX

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

+86.21.3760.1566 FAX

 

 

 

 

 

 

 

 

 

 

 

© 2011 Extron Electronics All rights reserved.

www.extron.com

68-1631-01 Rev. B

 

02 11

2

Image 2
Contents Setting Up the VLP 102 and VLH 102 Microphones Installing the VLC 202 Charging StationVLR 102SR If you are connecting a VLR 102SR secondary receiverPoleVault Switcher VLR
Related manuals
Manual 1 pages 58.63 Kb