Bosch Appliances 2.4 manual Release Date

Page 7

DCN Next Generation 2.40 Release Notes

en 7

4 Release 2.10

4.3 Known limitations

4.1General

4.1.1Release Date

November 8th 2005

4.1.2Firmware/FPGA versions

Product

FPGA

SW

FW

DCN-CCU

1.06

2.10.1178

3.40.1785

DCN-CON

1.0

--

--

DCN-CONCS

 

 

 

DCN-CONFF

1.0

1.00.XXXX

--

DCN-CONCM

 

 

 

DCN-DDB

--

1.3.XXXX

--

DCN-DDI

1.2

--

--

DCN-DIS

1.11

--

--

DCN-FCS

1.0

--

--

DCN-IDESK

1.3

1.20.XXXX

--

LBB 4402/00

--

2.10.1178

3.40.1785

PRS-4DEX4

--

2.10.1178

3.40.1785

LBB 4404/00

--

2.10.1178

3.40.1785

4.1.3Compatibility restrictions

The following versions are not compatible with this release:

Product

FPGA

SW

FW

DCN-CCU

≤1.06

--

--

LBB 4120

1.1

--

--

4.2Errata

4.2.1Integrus Manual: standby function When switching off the DCN Next Generation CCU, the Integrus transmitter indicates “Network Error” and not “standby”. However, the radiators do switch to the standby mode. When the DCN Next Generation CCU is switched on again, the Integrus transmitter and the radiators return to the “on” mode.

4.2.2Auxiliary function

The DCN-DISCS does not support “single delegate with auxiliary control mode” as mentioned in the Installation and User Instruction.

4.3.1Microphone will be reset to default after

de-init.

When a de-init is activated at the CCU the microphone is always set to microphone mode “open” with 2 active microphones.

4.3.2Use of Developers Toolkit

The developers toolkit provided on this CD-ROM can only be used with Windows 2000.

4.3.3Text “starting” remains on CCU In a system with an Audio Expander and an Integrus transmitter, the text “starting” can remain on the display of the CCU after start up. On the display of the Audio Expanders 'No Network' is flashing.

Switch the network mode of the Integrus transmitter to enabled and the problem will be solved.

4.3.4Network mode disabled results in faults When the network mode of a transmitter is set to disabled, while connected to a DCN Next Generation system, noise on the loudspeakers in the DCN Next Generation system can occur.

Switch the network mode of the Integrus transmitter to enabled and the problem will be solved.

Bosch Communications Systems 2007 March

Image 7
Contents DCN Next Generation 2.40 Release Notes Page Table of contents Introduction Release March 8th Firmware/FPGA versions Product Errata Integrus Manual Menu Item 4B Network ModeAdding system units to the optical ring When powered on ReleaseRelease Microphone will be reset to default after De-initUse of Developers Toolkit Release Date DCN-CON March 3th System reset of units after connecting new units to a trunk Audio Expander power consumption 7.6 WattJuly 23rd June 25th June 15th History