9.LCD
Data from the main CPU is decoded and displayed at the LCD unit.
10.EGS (Envelope Generator)
8 bits of data are received from the main CPU, and envelope and frequency data are sent to OPS.
11.OPS (Operator)
The OPS uses a sine table to generate waveform data to be sent to the DAC from the received envelope and frequency data.
The OPS permits combining the 6 operators in 32 different combinations. The combina- tions are called “algorithms”. One of the 6 operators is able to feed the sine table output back to the input. The feedback level and algorithm data is received from the main CPU.
12.DAC
A BA9221 DAC is used. The DAC converts the digital waveform data from the OPS to an actual analog waveform. The amplitude scale factor of the analog waveform is controlled via SF0 ~ SF3. This signal is then fed to the sample & hold and
13.MIDI (Musical Instrument Digital Interface)
Permits data transfer with other devices. Data is received by P3 of the main CPU via a
EGS
1 EGS Functions
Receives data from the CPU, generates envelope & frequency data, & transmits the gener- ated data to OPS.
(see EGS block diagram)
Data received from the CPU is latched in the EGS & sent to the internal data buss.
2 EGS Rate/Level Buffer
Rate refers to the time required for the next level to be reached. For example, Rl is the time