STOW CMS-44S CONCRETE MIXER — ELECTRIC MOTOR

Electric Motor

For maintenance care and operation of the electric motor, refer to your electric motor instruction booklet furnished with the electric motor.

Protect the electric motor from dust as much as possible and keep ventilating openings clean.

CAUTION:

DO NOT spray water at any time on the electric motor.

DO NOT operate electric motor in a explosive environment.

The electric motor used in this mixer is a single-phase 1.5 HP motor. The input voltage requirement for this motor is either 115 or 230 VAC only.

Electric Motor Connection

A 12 inch electrical cable (Figure 2) with a pigtail at one end is provided with the electrical motor for hookup to a power source. Table 1. shows the required NEMA connector for the desired motor horsepower rating. In addition, Table 2 also shows the matching NEMA approved connector for the required extension cord.

ALWAYS, make certain that the power source required for the electric motor is correct and always use the correct NEMA configuration plug. Failure to supply the correct voltage to the motor can severely damage the motor.

The electric motor supplied with the mixer is configured from the factoryfor115VACgroundedoperation.Makecertainthatthecorrect size grounded (3-wires) extension cord is used.See Table 5.

Motors can burn out when the line voltage falls 10% below the voltage rating of the motor. Failure to use proper voltage will cause the motor to overheat and actuate the overload switch.

If overload protection should actuate because of improper voltage or any other malfunction, turn the main switch on the motor to the "OFF" position and correct the problem, press the reset switch button, and turn the main switch to the "ON" position.

Table 5. Recommended Extension Cord Sizes

Electric

Input

50 ft.

75 ft.

100 ft.

200 ft.

Motor

Voltage

(15.24 m)

(22.86 m)

(30.48 m)

(60.96 m)

 

 

 

 

 

 

1/2 HP

115 VAC

No. 12

No. 10

No. 8

No. 6

 

 

 

 

 

 

Electric Motor Voltage Change Switch

1.ALWAYS make certain the electric motor's ON/OFF switch is in the "OFF" position and the power cord has been disconnected from the power source.

NEVER! disable or disconnect the

NOTE ON/OFF switch on the electric motor. It is provided for operator safety.Injury

may result if it is disable, disconnected or improperly maintained.

PAGE 18 —STOW CMS-44S CONCRETE MIXER— OPERATION & PARTS MANUAL — REV. #6 (04/02/07)

Image 18
Contents Concrete Mixer Page Heres HOW to GET Help Stow CMS-44S Concrete Mixer Table of Contents Parts Ordering Procedures When ordering parts Please supply the following informationStow CMS-44S Concrete Mixer Specifications Specifications Engine/Electric MotorStow CMS-44S Concrete Mixer Dimensions Mixer Mixer DimensionsStow CMS-44S Concrete Mixer Safety Message Alert Foryour Safety and the Safety of OthersGeneral Safety Stow CMS-44S Concrete Mixer Rules for Safe OperationStow CMS-44S Concrete Mixer Rules for Safe Operation EmergenciesStow CMS-44S Concrete Mixer Operation & Safety Decals Machine Safety DecalsStow CMS-44S Concrete Mixer General Information Stow CMS-44S Concrete Mixer Mixer Basic Components Mixer Major ComponentsStow CMS-44S Concrete Mixer Basic Engine Components Starting, OFF position stops engine operationsStow CMS-44S Concrete Mixer Handwheel Assembly AssemblyStow CMS-44S Concrete Mixer -TOWING Guidelines Tow Bar to Vehicle Connection Coupler OnlyMixer Tow Bar Vehicle Connection Pintle and Loop Stow CMS-44S Concrete Mixer Safety Chain Connection Tow Bar to Mixer ConnectionElectric Motor Electric Motor Voltage Change SwitchStow CMS-44S Concrete Mixer Electric Motor Electric Motor ConnectionSingle Phase Electric Motor with 12 inch Pigtail Cable Stow CMS-44S Concrete Mixer Electric MotorStow CMS-44S Concrete Mixer PRE-INSPECTION GAS Engine Stow CMS-44S Concrete Mixer Initial START-UP GAS Engine Starting the Engine Gasoline OnlyStow CMS-44S Concrete Mixer Initial START-UP ELECT. Motor Initial Start-up Instructions Electric Motor StartingStarting the Electric Motor Stow CMS-44S Concrete Mixer Operation OperationStopping the Mixer Electric Stow CMS-44S Concrete Mixer Maintenance Engine Stow CMS-44S Concrete Mixer Maintenance Engine MaintenanceStow CMS-44S Concrete Mixer Maintenance Mixer Grease Fittings MixerStow CMS-44S Concrete Mixer Maintenance Mixer Tires/Wheels/Lug NutsTo tighten wheel lug nuts Page Stow CMS-44S Concrete Mixer Troubleshooting Engine Engine TroubleshootingStow CMS-44S Concrete Mixer -TROUBLESHOOTING ENG./MIXER Engine TroubleshootingExplanation of Code in Remarks Column Items Found In the Remarks ColumnStow CMS-44S Concrete Mixer Suggested Spare Parts Qty DescriptionStow CMS-44S Concrete Mixer Name Plate and Decals Name Plate and DecalsStow CMS-44S Concrete MIXER- Name Plate and Decals Stow CMS-44S Steel Barrel Assy Steel Barrel AssyKing PIN Housing JackshaftPLUG, Expansion Ring GearStow CMS-44S Main Frame Assy Main Frame AssyWASHER, Lock 1/4 Handwheel Safety ChainGUARD, Gear Wheel ReplacesStow CMS-44S Axle Assy Axle AssyBearing Cone Lock NUT 1/2 NCOIL Seal Bearing CUPStow CMS-44S Cabinet Assy Cabinet AssyWASHER, Flat 5/16 Rubber ProtectorIncludes Item W Latch ASSY., CompleteStow CMS-44S GAS Engine Mounting Plate Assy GAS Engine Mounting Plate AssyRING, Retaining SWITCH, StopENGINE, Honda 3.9 HP Square KEY 1/4 X 35 MMStow CMS-44S Electric Motor Mounting Plate Assy Electric Motor Mounting Plate AssyDrive Pulley Stow CMS-44S Electric Motor Mounting Plate AssyMOTOR, Electric .5 HP Base Plate EngineHonda GX120K1QX2 Engine AIR Cleaner Assy AIR Cleaner AssyCollar B, AIR Cleaner GROMMET, AIR CleanerCOLLAR, AIR Cleaner GASKET, ElbowHonda GX120K1QX2 Engine Camshaft Assy Camshaft AssyARM, Valve Rocker SPRING, Weight ReturnROD, Push LIFTER, ValveHonda GX120K1QX2 Engine Carburetor Assy Carburetor AssyValve SET, Float PLATE, Lever SettingGasket SET Float SETHonda GX120K1QX2 Engine Control Assy Control AssySPRING, Governor ARM, GovernorROD, Governor SPRING, Throttle ReturnHonda GX120K1QX2 Engine Crankcase Cover Assy Crankcase Cover AssyBEARING, Radial Ball GASKET, Case CoverGASKET, OIL Filler CAP PIN A, DowelHonda GX120K1QX2 Engine Crankshaft Assy Crankshaft AssyCRANKSHAFT, H-TYPE Honda GX120K1QX2 Engine Cylinder Barrel Assy Cylinder Barrel AssySLIDER, Governor WEIGHT, GovernorPIN, Governor Weight SHAFT, Governor ARMHonda GX120K1QX2 Engine Cylinder Head Assy Cylinder Head AssyGASKET, Cylinder Head GUIDE, Valve OS OptionalCLIP, Valve Guide COVER, HeadHonda GX120K1QX2 Engine FAN Cover Assy FAN Cover AssyCOVER, FAN *NH1* Black GROMMET, Adjusting CoverWIRE, Stop Switch 370MM PLATE, Side OIL AlertHonda GX120K1QX2 Engine Flywheel Assy Flywheel AssyFlywheel FAN, CoolingPULLEY, Starter NUT, Special 14MMHonda GX120K1QX2 Engine Fueltank Assy Fuel Tank AssyTANK, Fuel *NH1* Black RUBBER, Supporter 107MMJOINT, Fuel Tank GASKET, Fuel Filler CAPHonda GX120K1QX2 Engine Ignition Coil Assy Ignition Coil AssyCoil ASSEMBLY, Ignition Honda GX120K1QX2 Engine Muffler Assy Muffler AssyGASKET, Muffler MufflerPROTECTOR, Muffler SCREW, TappingHonda GX120K1QX2 Engine Piston Assy Piston AssyPISTON, Standard BOLT, Connecting RODRing SET, Piston Standard PISTON, OSHonda GX120K1QX2 Engine Recoil Starter Assy Recoil Starter AssyRATCHET, Starter SCREW, SettingREEL, Recoil Starter GUIDE, RatchetNo Artwork Avalible Honda GX120K1QX2 Engine Gasket KIT Assy Gasket KIT AssyHonda GX120K1QX2 Engine Labels Assy Labels AssyLabel Caution Mark ChokeMARK, OIL Alert Payment Terms Page Service DEPARTMENT/TECHNICAL Assistance