SPECIFICATIONS
ARCHITECTURAL & ENGINEERING SPECIFICATIONS
The microphone shall be back- electret, condenser type with a frequency response of 50 Hz to 20 kHz. The microphone shall have a cardioid response pattern with a rear response that is typically
COLLET MOUNT INSTALLATION
Remove template from carton. Position the template at the desired position on the lectern. Placing it near the upper right or left corner of the reading surface is most practical.
Use tape to hold the template in place while you mark the location of center clearance and (3) mounting hole centers.
Remove the template and drill a 1"
PM™18S
(25.4 mm) center clearance hole. Next, drill (3) 3/32" (2.38 mm) screw pilot holes. After making sure the 1 1/2"
(38.1 mm) suspension foam washer is in the base of the collet mount, attach the collet mount to the lectern using the three mounting screws provided. Insert the connector end of the microphone into the top of the collet mount and gently press down to the desired depth. The connector end must penetrate the lower suspension foam
washer. CAUTION: Do not allow the output module cap to rest on the collet collar top. If this happens, the mechanical isolation system becomes ineffective.
Turn collet collar clockwise to tighten or counterclockwise to loosen the tension on the suspension system. Optimal tension is only enough to prevent the microphone from slipping downward on its own weight.
Holding the top portion of the microphone to prevent it from moving up, connect the microphone cable firmly into the microphone output module.
CAUTION: To preserve maximum vibration isolation, neither the output module nor the security clamp should come in contact with the collet or the mounting surface of the lectern.
SECURITY LOCK PROVISION
After the installation of the microphone, simply slip the security clamp around the microphone cable and position around the end of the output module beneath the mounting surface. Engage the jaws of the clamp and tighten securely by squeezing with your fingers or pliers.
While the clamp is in place, the microphone cannot be removed. This prevents theft and protects the mechanical isolation system from damage likely to occur if the XLR on the microphone cable is pulled through the collet.
To remove the microphone, disconnect the microphone cable from the output module and remove the security clamp by sliding one jaw downward until the teeth disengage.
2 YEAR LIMITED WARRANTY
NOTE: For details, refer to the warranty statement. For copies of this statement, contact Peavey Electronics Corporation, at P.O Box 2898, Meridian, Mississippi
2