Gemini PDM-24s manual Sampler Operation, Sample Recording, Sample Playback, Robo Play

Page 5

with a special curve designed for scratch mixing. Just purchase one of these crossfader units from your Gemini dealer and follow these instructions:

1.Unscrew the outside FADER PLATE SCREWS (B). Do not touch the INSIDE SCREWS (C).

2.Carefully lift the fader and unplug the CABLE (D).

3.Plug the new fader into the cable and place it back in the mixer.

4.Screw the fader to the mixer.

7.EQUALIZER SECTION: This unit features dual 7 band GRAPHIC EQUALIZERS (8, 23) to allow you to adjust the sound for any room. To activate the equalizer, press the EQ BUTTON (36) (the EQ LED will light). By adjusting any of the 7 left equalizer slide controls (8), you can cut or boost the tonal characteristics of the sound coming from the left speaker by ±12 dB. By adjusting any of the 7 right equalizer slide controls (23), you can cut or boost the tonal characteristics of the sound coming from the right speaker by ±12 dB. Deactivate the equalizer by pressing the EQ BUTTON (36) again (the EQ LED will turn off).

8.OUTPUT CONTROL SECTION: The level of the MAIN OUTPUT (43) is controlled by the MASTER (25) slide. Activating the MONO (24) button (the mono LED will light) makes the overall output mono. The BOOTH (37) control adjusts the level of the BOOTH OUTPUT (44). HINT: The BOOTH OUTPUT is used by some DJs to run monitor speakers in their DJ Booth. You can also use it as a second ZONE or AMP output.

NOTE: The REC OUTPUT (43) has no level control. The level is set by the channel slides of the selected channel. The tonal qualities can be controlled by the equalizers.

9.TALKOVER SECTION: The purpose of the talkover section is to allow the program playing to be muted so that the mic can be heard above the music. The MIC/TALKOVER SWITCH (7) controls MIC 1 and MIC 2 and has three settings. When the MIC/TALKOVER SWITCH (7) is in the bottom position, MIC 1 and MIC 2 and talkover are off. When the MIC/TALKOVER SWITCH (7) is in the center position MIC 1 and MIC 2 are on, the MIC INDICATOR (6) will glow, but talkover is off. When the MIC/TALKOVER SWITCH (7) is in the top position, MIC 1 and MIC 2 and talkover will be on and the volume of all sources except the Mic inputs are lowered by 16 dB. The TREBLE (2) and BASS (3) controls allow you to fully adjust the tone of MIC 1 and MIC 2. MIC 1 LEVEL (5) controls the level of MIC 1. The MIC 2 LEVEL (4) controls the level of MIC 2.

10.CUE SECTION: By connecting a set of headphones to the HEADPHONE (40) jack, you can monitor any or all of the channels. Press the CUE/SAMPLE ASSIGN (21) buttons for channels 1 - 4 to select the channel or channels to be monitored and their respective LED indicators will glow. Press the CUE/SAMPLE ASSIGN (20) button to monitor MIC 1 and MIC 2. The CUE/SAMPLE ASSIGN (20, 21) buttons are also used to assign samples (see Sampler Operation for more details). Press the CUE SAMPLER (26) to monitor samples. Use the CUE LEVEL (39) control to adjust the cue volume without effecting the overall mix. By moving the CUE PGM PAN (38) control to the left you will be able to monitor the assigned cue signal. Moving the control to the right will monitor the PGM (program) output.

11.DISPLAY: The DISPLAY (22) indicates either the MASTER output left and right levels.

Sampler Operation

GENERAL INFORMATION: The PDM-24s Sampler uses Dynamic RAM memory and a 12 bit microprocessor controller. The full bandwidth results in true sound reproduction.

MEMORY INFORMATION: The PDM-24s comes equipped with five MEMORY BANKS (31). The two banks marked 2 & 2 are two seconds in length, the two banks marked 4 & 4 are four seconds in length and the bank marked 12 is twelve seconds in length. These banks are separate and can not be linked. You can store a different sample in each bank but they must be recorded individually and they must be played one at a time.

SAMPLE RECORDING:

1.Put the MODE SELECTOR (30) switch into the WRITE position.

2.Select the source you want to sample from by pressing the appropriate CUE/SAMPLE ASSIGN (20, 21) button.

3.Select the memory bank you want to record into, by pressing the proper MEMORY BANK (31) button.

4.The PDM-24s comes equipped with a sampler PITCH (28) control. To get a perfect sample, set the control to its center position and record the sample. During playback, raising or lowering the control will raise or lower the pitch of the sample playback. The center position will remain as normal pitch.

HINT: You can record a sample with the PITCH (28) control in any position. Whatever that position is will become normal sound. If you start to record a sample with the PITCH (28) control set at minimum (this now becomes your normal pitch), by increasing the pitch to maximum, the pitch effect will double in speed. Recording at maximum and lowering to minimum will do exactly the opposite.

5.Tapping the START/STOP (32) button begins the sampling process (the SAMPLER INDICATOR will illuminate RED). Tapping the START/STOP (32) button a second time ends the sample (the SAMPLER INDICATOR will turn off). If you do not tap the START/ STOP (32) button a second time, the sampling process will stop automatically after 2, 4 or 12 seconds depending on which MEMORY BANK (31) was selected.

SAMPLE PLAYBACK:

1.Put the MODE SELECTOR (30) switch into the SINGLE or REPEAT position.

2.Select the memory bank you wish to play by pressing the proper MEMORY BANK (31) button.

3.Tapping the START/STOP (32) button with the MODE SELECTOR

(30)switch in the SINGLE position will cause the sampler to playback one time (the SAMPLER INDICATOR will illuminate GREEN). Every push of the START/STOP (32) button will restart the sample from the beginning. Rapid pressing of the START/STOP (32) button will cause a stuttering effect. Once the sample has started playback and the START/STOP (32) button is not pushed a second time, the sample will play to the end and then stop (the SAMPLER INDICATOR will turn off).

4.Tapping the START/STOP (32) button with the MODE SELECTOR

(30)switch in the REPEAT position will cause the sample to

continuously play over and over (the SAMPLER INDICATOR will illuminate GREEN). The START/STOP (32) button will act as an on/ off switch. The first push will start the sample, the second push will stop it. The SAMPLER LEVEL (27) controls the level of the sample.

ROBO PLAY:

1.With the ROBO PLAY (29) button in the OFF POSITION (the ROBO PLAY INDICATOR will be OFF) and the MODE SELECTOR (30) switch in either the SINGLE or REPEAT mode, pressing the START/ STOP (32) button will cause the sample to play along with the selected source.

Page 4

Image 5
Contents PDM-24s Page Page Using the Ground Lift Switch FeaturesIntroduction ConnectionsSample Recording Sampler OperationSample Playback Robo PlayInputs SpecificationsOutputs GeneralGemini Sound Products Corp All Rights Reserved

PDM-24s specifications

The Gemini PDM-24s is a cutting-edge processing device designed for precision measurement and data management in various applications, particularly in the fields of industrial automation and scientific research. This advanced system distinguishes itself with its robust features, comprehensive technology, and user-friendly characteristics that cater to the demands of modern users.

One of the main features of the Gemini PDM-24s is its high-performance data processing capabilities. Equipped with a powerful processor and advanced algorithms, the device can handle complex calculations and large data sets with remarkable speed and accuracy. This allows users to obtain precise measurements and make informed decisions quickly, which is crucial in fast-paced environments.

Incorporating state-of-the-art sensors, the Gemini PDM-24s offers exceptional measurement accuracy across various parameters. Its multi-channel capacity enables simultaneous data collection from different sources, enhancing productivity and efficiency. The device is designed to interface with a wide range of sensors, making it versatile for various applications, from manufacturing to laboratory analysis.

Another significant characteristic of the Gemini PDM-24s is its adaptability. The unit supports multiple communication protocols, allowing seamless integration with existing systems and equipment. Users can easily connect the PDM-24s to computers, control systems, or cloud platforms for real-time data monitoring and analysis. This feature facilitates remote access and collaboration, empowering teams to work together, regardless of their location.

The Gemini PDM-24s also boasts a user-friendly interface, featuring an intuitive touchscreen display that simplifies navigation and operation. Users can easily configure settings, view data trends, and generate reports without extensive training. The system's customizable dashboards allow users to tailor their viewing experience, ensuring that critical information is readily accessible.

Additionally, the Gemini PDM-24s is designed with durability in mind. Its rugged construction ensures reliable performance even in harsh environments, while built-in safety features protect against unexpected failures. This reliability minimizes downtime and maintenance costs, making it an ideal choice for industries that require consistent performance.

In summary, the Gemini PDM-24s combines high-performance data processing, exceptional measurement accuracy, adaptable communication options, user-friendly interface, and robust construction. These features make it a versatile and reliable solution for various industrial and scientific applications, empowering users to achieve optimal performance in their respective fields.