PRO MIXER DX052
These are the LINE inputs to connect a tape deck, CD or MD player etc.
The GND connectors ground the turntables.
The DX052 features an integrated effects loop for the connection of an external effects device/sampler. The MONITOR signal is taken at the SEND output and routed, for example, to a reverb processor. Thus, the signal at the SEND connector is identical to the headphones signal.
The externally processed signal is added to the MASTER output signal via the RETURN connectors. The effect signal volume may only be adjusted at the output control of the effects device itself.
Fig. 3.2: PRO MIXER DXD052 rear panel connectors
The MASTER output is for connecting to an amplifier and can be adjusted with the MASTER level control.
+Always turn the power amps on last to avoid inrush currents that can easily damage your speakers. And, to avoid sudden and unpleasant surprises for your ears, make sure there is no signal at the DX052 before turning on the power amps. To be sure, slide all the faders to the bottom and switch all controls to the zero position.
Using the TAPE output you can record your music by connecting devices such as tape decks, DAT recorders etc. Unlike the MASTER output, the output volume is fixed, making it necessary for you to adjust the input level on the recording device.
The POWER switch powers the DX052 on. You should always make sure that the POWER switch is in the “Off” position when initially connecting the unit to the mains.
+Please take note: Merely switching the unit off does not mean that it is fully disconnected from the mains. When not using the unit for prolonged periods of time, please unplug the unit’s power cord from the power outlet.
FUSE HOLDER / VOLTAGE SETTING. Before connecting the unit to the mains, ensure that the voltage setting matches your local voltage. Blown fuses should only be replaced by a fuse of the same type and rating. On some units, the fuses holder can be switched to one of two positions, i.e. 230 V and 120 V. Please note: should you desire to operate the unit outside Europe at 120 V, a higher fuse rating is required.
This is the connector for the power cable. This is where the advantage of a sophisticated internal power supply can be seen: the pulse behaviour of each amplifying circuit is mainly determined by the voltage reserves available. Each mixing console is equipped with numerous operational amplifiers (op amps) to process line level signals. Due to limited output of their power supplies, many mixing consoles show signs of “stress” when subjected to heavy loads. But not your DX052: the sound is always clear and transparent.
+To disconnect power from main, pull out the main cord plug. When installing the product, ensure that the plug is easily accessible. If mounting in a rack, ensure that the mains can be easily disconnected by a plug or by an
SERIAL NUMBER. Please take the time to complete and return the warranty card within 14 days of the date of purchase. Or, simply register online at www.behringer.com.
4. SPECIFICATIONS | |
AUDIO INPUTS |
|
Mic | 40 dB Gain, |
| electronically balanced input stage |
Phono 1 and 2 | 40 dB Gain, unbalanced inputs |
Line 1 and 2 | 0 dB Gain, unbalanced inputs |
Return | 0 dB Gain, unbalanced input |
AUDIO OUTPUTS |
|
Master | max. +19 dBu @ +10 dB (Line in) |
Tape | typ. 0 dBu |
Send | typ. 0 dBu |
Phones | max. 180 mW @ 75 Ω / 1% THD |
EQUALIZER |
|
Stereo Low | +12 |
Stereo High | +12 |
Mic Low | +12 |
Mic High | +12 |
GENERAL |
|
> 87 dBu (Line) | |
Crosstalk | > 70 dB (Line) |
Distortion (THD) | < 0,05% |
Frequency response | 10 Hz - 55 kHz |
POWER SUPPLY |
|
Mains voltages | USA/Canada |
| 120 V~, 60 Hz |
| Europe/U.K./Australia |
| 230 V~, 50 Hz |
| Japan |
| 100 V~, 50 - 60 Hz |
| General export model |
| 120/230 V~, 50 - 60 Hz |
Power consumption | 13 W |
Fuse | 100 - 120 V~: T 500 mA H |
| 200 - 240 V~: T 250 mA H |
Mains connection | Standard IEC receptacle |
DIMENSIONS/WEIGHT |
|
Dimensions (H x W x D) | approx. 4 3/10" (109.2 mm) |
| x 10 2/5" (264 mm) |
| x 12 2/5" (315 mm) |
Weight | approx. 2.3 kg (5 1/16 lbs) |
BEHRINGER makes every effort to ensure the highest standard of quality. Necessary modifications are carried out without notice. Thus, the specifications and design of the device may differ from the information given in this manual.
8 | 4. SPECIFICATIONS |