Philips DP 6000, LBB 5800 installation instructions Menu Alarm KEY, Edit Functional Relay Status

Page 8

DP 6000 DIGITAL PAGING SYSTEM

INSTALLATION INSTRUCTION 69

 

 

 

December 1997

Page 8/15

 

 

 

The display will now show “Sel. Chan. Nr”, select

the channel to be edited (01 - 16) and the display will show the programmed auto scan

status of the channel e.g.

 

“e

c

xx

a m yy - 1 - zz”

 

 

 

Location =

1

2

3

4

5 6 7

 

Where e

=

auto scan enabled (or “d” for auto-scan disabled)

 

c

=

codinf value for an auto scan with manual acknowledge (see table 2, bleep patterns).

xx

=

auto scan repeat time in minutes (00 - 99)

 

a m

=

auto scan acknowledge type

key

4 - 1)

A = auto reply

 

 

 

 

 

 

key

4 - 2)

M = manual reply

 

 

 

 

 

 

key

4 - 3)

AM = auto + manual . This selection must be combined

with location “6” (Call Ratio) which determines how many auto-scans (max. 16) precede the required manual acknowledge e.g. if “5” is selected at location “6” then there will be 5 auto-scans and the next will require a manual response from the Transceiver holder.

yy

=

manual acknowledge time in seconds (00 - 99)

1

=

auto to manual acknowledge call ratio (0 - F)

zz

=

the selected channel number - not programmable

Keystrokes 1 - 7 will select the location on the display to be edited e.g.

if the auto scan repeat time only has to be edited, then press key

3 and enter the new time. (to disable auto-scan, press “1 “ followed by

“0” . Pressing “1” followed by “1” enables auto-scan.

Use the PROGRAM key to enter the completed input.

 

Eronneous keystrokes generate the error bleeps.

 

 

8

MENU - “ALARM KEY”

Edit Functional Relay Status

This menu is used to program the relays to be active by system functions independantly of each other.

a)

Relay function assignment

-

A,M,N,S,F,D,C. (default: I.I.I.I.I.I.I)

b)

Relay action delay time

 

-

00 - 99 seconds

c)

Relay pulse time

 

 

-

00 - 99sec. (00=infinate)

d)

Relay stand-by status

 

-

“energised”/”de-energised”

e)

Alarm call transmission

 

-

“enabled”/”inhibited”

 

 

Position

 

Indication

Function

 

Display indication for function

1

-

A

-

No manual alarm

 

 

2

-

M

-

Manual alarm

 

 

3

-

N

-

No move alarm

 

 

4

-

S

-

No move switch “off”

 

 

5

-

F

-

Field call received

 

 

6

-

D

-

Direct call activated

 

 

7

-

C

-

Auto scan auto acknowledge not received

If the relay is inhibited for a function, the display will show “I” instead of the function character

When this menu is opened, the display info will differ depending on how many FCPs are connected.

1.More than one FCP connected:

Display shows “Sel.FCP Nr. “ and the lowest allocated address, of which the status is “present”, is displayed.

Scroll the FCP addresses with the PROGRAM key and enter the displayed address with the DIRECT CALL key.

The display shows “Relay Nr.” now select relay number (1 - 3) and enter by the PROGRAM key.

2.

One FCP connected:

The display shows “Relay Nr.” now select relay number (1 - 3) and enter

 

 

by the PROGRAM key.

Image 8
Contents General Information Programming the FCPSetting The Desk Work Mode Opening The EditorClosing The Editor Bleep TonesEntering The Program Variables FCP ProgrammingPS 6000 menu selection Address Allocation Addressing an FCPCommmand FCP Status ControlENABLE/INHIBIT the Call String Menu Direct Call KEYEdit Direct Call Editing the Direct Call StringEditing the Alarm Call String Manual / Auto Acknowledge ModeAlarm Call Repeat Time Editing the PST Acknowledge AddressManual Acknowledge Time Menu Monitor KEYMenu a Auto Scan Call Time may not be set to 255 secondsMenu Alarm KEY Edit Functional Relay StatusDelay Action Time Alarm Call TransmissionFunction Assignment Pulse TimeWiring Details PS 6000 and DP 6000 System Wiring 11/15Central Transmitter I I I I FCP Default Values Function13/15 Codinf Digit Function Call Panel FunctionLBB 5800 High Performance Control Desk 15/15

DP 6000, LBB 5800 specifications

The Philips LBB 5800 and DP 6000 represent a groundbreaking evolution in audio and communication technology, designed specifically for public address systems, professional sound reinforcement, and communication in diverse environments. These devices cater to a wide range of applications, ensuring superior performance and clarity for users in various sectors, including education, healthcare, and corporate environments.

One of the main features of the Philips LBB 5800 is its user-friendly interface, which facilitates easy operation for individuals of all skill levels. The device boasts a robust design, ensuring durability and reliability even in demanding situations. The LBB 5800 is equipped with a powerful amplifier capable of delivering clear, crisp sound across large areas, making it an ideal choice for auditoriums, conference halls, and outdoor events.

The DP 6000, on the other hand, is a sophisticated digital audio processing unit that allows for enhanced sound quality and flexibility in audio management. It features advanced signal processing technology, enabling users to tailor audio output to suit specific environments or audiences. This adaptability ensures that every sound is transmitted accurately, minimizing distortion and maximizing clarity.

Both the LBB 5800 and DP 6000 incorporate cutting-edge digital signal processing (DSP) capabilities, which elevate the overall listening experience. With intelligent feedback suppression, automatic gain control, and equalization options, these devices can dynamically adjust audio output based on real-time environmental conditions, ensuring optimal sound quality at all times.

Another noteworthy characteristic is the connectivity options available with these systems. The LBB 5800 and DP 6000 support various input and output formats, including XLR, RCA, and network audio solutions. This makes integration with existing sound systems or expansion options simple and efficient.

Furthermore, both models are designed with scalability in mind, allowing users to expand their system as needed. This is particularly beneficial for growing organizations that require flexible solutions to adapt to changing needs. The ability to connect multiple units seamlessly enhances the overall capabilities of a sound system.

In conclusion, the Philips LBB 5800 and DP 6000 provide a powerful combination of features, advanced technologies, and characteristics that make them a top choice for professionals seeking high-quality audio and communication solutions. Their durability, flexibility, and superior sound processing capabilities ensure they meet the demands of various applications, delivering exceptional performance every time.