Philips CCD dimensions Alarm inputs, Position, Focus adjustment

Page 4

Alarm inputs

The camera has a three-pole terminal block (fig. A-13) for connecting alarm sensors, such as doorcontacts. For normally open (N.O.) sensors, connect to contacts N.O.. For normally closed (N.C.) sensors, connect to contacts N.C..

Position

First you need to determine where the camera is to be installed. The best results are obtained when the camera looks a little downwards and not into a bright source of light.

Hold the camera in your hand at the spot where you want to install it and check on the monitor whether the camera does actually cover the required area from that spot.

Fasten the mounting bracket to the ceiling, the wall, or another even and firm surface by means of the supplied screws and plugs.

Tighten the knob (fig. A-3) of the ball-and-socket joint.

Fasten the camera to the bracket by screwing the mounting hole in the back or bottom of the camera (fig. A-1) onto the threaded end (fig. A-2).

Loosen the knob of the ball-and-socket joint (fig. A-3) and, if necessary, the screw (fig. A-4) on the mounting bracket and direct the camera accurately at the object or area you want to have on screen.

The knob and screw can be tightened again when the camera is in the required position.

Remark: The camera can also be mounted on any other camera tripod standardly provided with a 1/4" 20 UNC thread.

Check if the cable length compensation (fig. A-15) selector is set to the correct length. The length set must be the same as the length of the system cable (0-300m/900ft max.) connecting monitor and camera.

Focus adjustment

Adjust the focus ring (fig. B-1) of the camera lens to obtain an optimal image sharpness.