Schneider Electric VSE 002 user manual Module connection to a PC, Ordering codes

Page 6

VSE 002 External RS-485 Module

7 Module connection to a PC

 

 

7. Module connection to a PC

The module can be used with a PC, the required cable is described in figure 4. When used with a PC an external power supply is needed (e.g. type Phoenix Contact 100 – 240 AC/10-15 DC/2, Order-No. 29 83 75 6).

PC serial interface

Function

Pin

 

number

 

 

CD (in)

1

RXD (in)

2

 

 

TXD

3

(out)

 

 

 

DTR

4

(out)

 

GND

5

 

 

DSR (in)

6

 

 

RTS

7

(out)

 

 

 

CTS (in)

8

 

 

-

9

 

 

VSE 002

Pin Function number

1-

2RXD (in)

3TXD (out)

4RTS (in)

5-

6-

7GND

8-

9+8V (in)

Figure 4. PC interface cable

8. Ordering codes

VSE 002 RS-485interfacemodule

6

VVSE2/EN M/B006

Image 6