Cisco Systems SMD48FXSE, VG350 specifications Access to Chassis, Chassis Grounding

Page 37

Chapter 3 Planning Your Installation

Location and Mounting Requirements

Enclosed Racks

Caution Enclosed racks must have adequate ventilation. An enclosed rack should never be overcrowded and should have louvers and a fan.

If the Cisco VG350 Voice Gateway is installed in an enclosed rack with a ventilation fan at the top, make sure that heated air drawn upward from other equipment does not prevent adequate cooling.

If the chassis is installed using slide rails, check for blocked ventilation ports when it is in position in the rack or cabinet. Make sure that the ventilation ports of the Cisco VG350 Voice Gateway are not blocked.

Tip Baffles can help isolate exhaust air from intake air. Baffles also help draw cooling air through the cabinet. The best location for the baffles depends on the airflow patterns in the rack. You can test the airflow by experimenting with different equipment arrangements.

Bench-Mounted

If the unit is placed on a bench-top, do not stack other equipment or paper on the chassis. Provide plenty of space for air circulation (front to back). Inadequate ventilation can result in overheating and damage.

Access to Chassis

Allow space at the rear of the chassis for cable connections. Also consider the need to access the chassis for future upgrades, maintenance, and troubleshooting.

Chassis Grounding

Chassis grounding is provided through the power cable, which uses a standard grounding plug. However, the chassis also requires a reliable earth ground using the earth ground lug and hardware provided.

Cisco VG350 Voice Gateway Hardware Installation Guide

3-2

OL-25970-01

 

 

Image 37
Contents Americas Headquarters Cisco VG350 Voice Gateway Hardware Installation GuidePage N T E N T S Grounding Site Log Organization AudienceChapter Title Description Convention Description ConventionsBewaar Deze Instructies Safety WarningsSäilytä Nämä Ohjeet Conservez CES InformationsConservare Queste Istruzioni Bewahren SIE Diese Hinweise GUT AUFTA Vare PÅ Disse Instruksjonene Guarde Estas InstruçõesSpara Dessa Anvisningar GEM Disse Anvisninger Xiii Xiv Obtaining Documentation Related DocumentationCisco.com Obtaining Technical Assistance Documentation FeedbackOrdering Documentation Cisco Technical Support WebsiteDefinitions of Service Request Severity Submitting a Service RequestObtaining Additional Publications and Information USB OverviewAC OK VG350 Voice Gateway ChassisConfiguration Options Interfaces and Service CapabilitiesSFP Physical Description and LEDs LED IndicatorsLED Color DescriptionCF0/CF1 Description Specification SpecificationsSFP Transportation and Storage SD/EMI Configuration Methods Configuration ConnectionsSoftware Elements OL-25970-01 Cisco Double-Wide High Density Analog Service Modules FXS-E SM-D-72FXS SM-D-48FXS-EGrounding Installing SM-D-72FXSConnecting SM-D-48FXS-E Installing SM-D-48FXS-EFXO Fail-Over Bypass Ports Faceplate Label RJ-11 OUT RJ-11 Power on Power OFFFXO BYPASS-0Cisco SM-D-48FXS-E Service Module Specifications Cisco SM-D-72FXS Service Module SpecificationsPhysical Description and LEDs EN LEDOnline Insertion and Removal Port Numbering ConventionsInsertion Insertion and Removal StepsLocation and Mounting Requirements Temperature Control and VentilationChassis Grounding Access to ChassisPower Suppy Considerations Power SourceCable Types Distance Limitations for Interface CablesGigabit Ethernet Maximum Distance FXS Analog Voice Port Maximum DistanceInterference Considerations OL-25970-01 Installing the Cisco VG350 Voice Gateway Maintaining Safety with Electricity Safety RecommendationsPage Safety Tips General Safety PracticesPreventing Electrostatic Discharge Damage Site LogInstallation Checklist Keeping Track-ChecklistTask Verified by Date Unpacking and Inspection Mounting Tools and EquipmentOL-25970-01 Checklist for Power-On Powering On the Cisco VG350 Voice GatewayPower-On Procedure Continue with the Troubleshooting section on Symptom Possible Cause Corrective Action TroubleshootingOL-25970-01 Console and Auxiliary Port Cables and Pinouts Cable Specifications and InformationRTS CTS DTR DSR Console Port to PCGND DSR DTR CTS RTSFigure A-2 Console Port to Ascii Terminal-Cable and Adapter Console Port to Ascii TerminalAlternative Connections to Terminal and Modem Auxiliary Port to ModemRTS DTR DSR DCD CTSGigabit Ethernet Port Pinouts RJ-45 Pin SignalTX+ RX+Analog Voice Multiport Pinouts RJ-21X/CA21A Port Connector Pin Number SignalRing Tip 25, 50, 51