//_ WARNING
(a)Do not store a spare
(b)Never fill the cylinder beyond 80 percent full.
(c)If the information in"(a)" and "(b)" is not followed exactly, a fire causing death or serious injury may occur.
FOR YOUR SAFETY
1.Do not store or use gasoline or other flammable material and liquids in the vicinity of this fireplace or other appliance.
2.ALP cylinder not connected for use must not be stored in the vicinity of this or any other appliance.
IMPORTANT; This fireplace is only for use with LP type of gas as equipped from the manufacturer and is not convertible for use with other gases.
IMPORTANT; This fireplace may not be used for preparing food. Gases and/or food particles may fall into the appliance and inhibit proper operation.
Important safety rules:
YOUNG CHILDREN should be carefully supervised when they are in the area of the fireplace.
NEVER hang anything including clothes or other flammable items on the fireplace.
The screens installed in this fireplace must be in place at all times when in operation to prevent foreign objects from entering the unit.
For proper ventilation around the unit, do not obstruct the upper and lower vent louvers.
The fireplace should be inspected before first use and at least annually by a qualified service person. More frequent cleaning may be required depending on area conditions.
Keep burner and control compartment clean. See installation and operating instructions.
1 Clearance from combustibles:
Proper clearance from combustible materials must be maintained at all times (See Fig 1 for minimum clearance)
Combustible materials include wood, compressed paper, plant fibers, plastic, plexiglass or other materials capable of being ignited and burned.
Such materials shall be considered combustible even though flameproof,
Unit to walls: | 24 Inches |
Unit to ceiling: | 24 Inches |
Fig 1 Minimum clearance from combustibles.
24inches
2.The gas inlet supply and normal operating manifold pressure for fireplace is as follows. For gas supply line pressures in excess of 14 "W.C., consult with your representative or the factory.
Type of Gas | Liquid Propane | |
Maximum | inlet pressure | 14 "W.C. |
Minimum | inlet pressure | 11 "W.C. |
Manifold | pressure | 9 "W.C. |
Gas Rating | 41,000 BTU/hr |
3.The fireplace must be inspected before each use and annually by a qualified service person.
AIt gas connections should be checked for leaks utilizing a soap solution. Never use a flame for this purpose.
The flame pattern should be visually checked whenever the fireplace is operated.
Yourfireplace area must be kept clear and free of combustible materials, gasoline and other flammable vapors and liquids.
Clean your fireplace only with noncombustible,
4.Your fireplace has been designed with several safety features as follows.
A thermal fuse for overheating
Automatic ignition.
Safety combination valve shut off.
The operating condition is controlled and diagnosed by a micro processor.
The micro processor is an advanced feature which also makes it easy for one touch operation with remote control or manual push button.
Any modification to the fireplace not described in the installation instructions may compromise the safety of this fireplace and will void the warranty.
3