Desa VPN36 3-SIDED Flashing Installation, Storm Collar Installation, Terminations

Page 11

FLASHING INSTALLATION

Determine the flashing to be used with the roof-opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles.

DO NOT NAIL THROUGH FLASHING CONE.

STORM

CHIMNEY PIPE

 

COLLAR

 

 

 

OVERLAP

FLASHING

 

SHINGLES

 

TOP AND

 

 

SIDES ONLY

NAIL ONLY

 

OUTER

 

 

PERIMETER

 

OF FLASHING

 

 

UNDERLAP

 

 

SHINGLES

 

Figure 25

AT BOTTOM

 

STORM COLLAR INSTALLATION

Place storm collar over pipe and slide down until snug against the open edge of the flashing (see Figure 26).

CHIMNEY

PIPE

Figure 26

Apply waterproof caulking to all seams and notched around storm collar and also at base around shingles.

TERMINATIONS

The firebox system must be terminated with the listed round top or chase terminations, In any case, refer to the installation instructions supplied with the termination.

The terminations approved for this firebox are VRTL-10Dwhich can be used for flashing or chase and VETL-10Dfor chase style termina- tion only. Figure 27 shows an VRTL-10D round top termination.

STAINLESS

VRTL-10D

INNER FLUE

 

PIPE

 

SECURE TERMINATION TO OUTER PIPE WITH

(3) SCREWS

 

APPLY WATERPROOF

OVERLAP

CAULKING

STORM COLLAR

SHINGLES

(TOP AND

 

SIDES OF

FLASHING

FLASHING BASE)

 

UNDERLAP

SHINGLES

Figure 27

CAUTION: DO NOT SEAL OPENINGS ON THE ROOF- TOP FLASHING. FOLLOW THE INSTALLATION IN- STRUCTIONS PROVIDED WITH THE TERMINATION BEING USED.

CHASE INSTALLATIONS

Instructions for chase installations are included with the chase style termination chosen although it is worthy to mention here that in a multiple chase installation, provide adequate distance between ter- minations or smoke spillage from one termination to another may occur. We suggest they be separated at least 30" center to center and stacked at a vertical height difference of 18" vertically from one termination to the other (see Figure 28).

 

 

 

18"

MIN.

 

 

 

 

30"

 

 

 

TYP.

MIN.

 

 

 

 

 

 

 

 

 

30"

MIN.

 

Figure 28

 

 

 

 

 

55505

11

Image 11
Contents Save this Book For Your SafetyCheck Local Codes Prior to Installation Clearances Chimney Pipe InstallationGAS Line Installation N T E N T SSelecting Location IntroductionBefore YOU Begin Minimum Clearances to Combustibles are Mantel ClearancesØ15 Outer Pipe Hearth ExtensionsFactor x 1 = Thickness required Lineal Gain Pipe InstallationSupport Sections Elbow Offset InstallationFirebox Spacer Finishing Your Chimney System Foot Rule Rise and OffsetsMaximum Chimney Height Chimney MaintenanceRoof Opening Chart Minimum Chimney HeightTerminations Flashing InstallationStorm Collar Installation Chase InstallationsFlashing Mantels Cabinet Door InstallationFinishing Your Firebox Firebox FacingDamper Mechanism Operating Guidelines and Maintenance InstructionsGrate Glass DoorsECONO-TOP Termination VETL-10D Replacement and Accessory Parts