Vulcan-Hart MG24CB Leveling, GAS Connections, Testing the GAS Supply System, Ventilation

Page 7

LEVELING

Place a carpenter's level on top of the charbroiler. Level the charbroiler front to back and side to side by turning the adjustment screw at the bottom of each leg.

GAS CONNECTIONS

Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.

Location of the gas inlet is at the rear on the left side. Codes require that a gas shutoff valve must be installed in the gas line ahead of the charbroiler.

Connect gas supply. Make sure the pipes are clean and free of obstructions.

Charbroilers are equipped with fixed burner orifices for use with natural or propane gas and no adjustments are necessary.

Natural gas pressure regulators are preset for an outlet pressure of 3.7" W.C. (Water Column); propane gas pressure regulators are preset for 10" W.C.

WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

TESTING THE GAS SUPPLY SYSTEM

When gas supply pressure exceeds 1/2 psig (3.45 kPa), the charbroiler and its individual shutoff valve must be disconnected from the gas supply piping system.

When gas supply pressure is 1/2 psig (3.45 kPa) or less, the charbroiler should be isolated from the gas supply system by closing its individual manual shutoff valve.

VENTILATION

It is required that the exhaust fumes be ventilated to the outside of the building through a ventilation system installed by qualified personnel.

Information on the construction and installation of ventilating hoods may be obtained from the standard for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

— 7 —

Image 7
Contents Installation For Your Safety Important for Your SafetyTable of Contents Unpacking InstallationLocation Canada Installation Codes and StandardsAssembly United States of AmericaPage Ventilation Testing the GAS Supply SystemLeveling GAS ConnectionsLighting Instructions OperationControls Before First USEExtended Shutdown Using the CharbroilerTurning the Charbroiler on Turning the Charbroiler OFFCleaning Service and Parts Information MaintenanceLubrication