Frigidaire Outdoor Kitchen Grill warranty GAS Installation, Tank Information, Tank USE

Page 10

Gas Requirements

L.P. GAS INSTALLATION

Frigidaire Gallery Gas Grills that are set to operate with L.P. gas come with a high capacity hose and regulator assembly.

(Note: Only use the pressure regulator and hose assembly supplied with the grill or a replacement pressure regulator and hose assemblies specified by Frigidaire). This assembly is designed to connect directly to a standard 20 lb. L.P. cylinder. L.P. Cylinders are not included with the grill. L.P. Cylinders can be purchased separately at an inde- pendent dealer.

LP hose/ regulator supplied with head only grill. (Type 1 connector)

LP hose/ regulator supplied with com- plete grill and cart. (Type 1 connector)

L.P. TANK INFORMATION

Never use a dented or rusted L.P. tank or cylinder with a damaged valve.

L.P. cylinders are equipped with an O.P.D (Overfilling Prevention Device). The device shuts off the flow of gas to a cylin- der after 80% capacity is reached. This limits the potential for release of gas when the cylinder is heated, averting a fire or possible injury.

The L.P. cylinder must have a shut-off valve terminating in an L.P. gas supply cylinder outlet specified, as applicable, for connection No. 510 in the standard for compressed gas cylinder valve outlet and inlet connection ANSI/CGA-V-1. Cylinders must not be stored in a building, garage, or any other enclosed area. (The L.P. cylinder must have an overfill protection device, OPD, on it.)

The L.P. gas supply cylinder must be constructed and marked in accordance with the specifications for L.P. gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CAS-B339, “Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.”

L.P. TANK USE

When turning the L.P. tank on, make sure to open the valve SLOWLY two (2) complete turns to insure proper gas flow. Most gas tanks now come equipped with a leak detector mechanism internal to the tank, when gas is allowed to escape rapidly it shuts off the gas supply. Opening the valve rapidly may simulate a gas leak, causing the safety device to activate, restricting gas flow causing low flames. Opening the valve slowly will insure this safety feature is not falsely triggered.

When not in use, gas supply cylinder valve is to be in the “OFF” position.

The tank supply system must be stored upright to allow for vapor withdrawal.

The regulator and hose assembly must be inspected before each use of the grill. If there is excessive abrasion or wear or if the hose is cut, it must be replaced prior to the grill being used again.

Cylinders must be stored outdoors out of the reach of children and must not be stored in a building, garage or any other enclosed area.

Only a qualified gas supplier should refill the L.P. tank.

Do not store a spare L.P. gas cylinder under or near the grill.

10

Image 10
Contents Use & Care Manual Please Read and Save These Instructions Welcome & CongratulationsPlease attach sales receipt here for Future reference General Safety Instructions Important Safety InformationGrill Features GL38 Interior Parts Installation Grill AssemblySide Shelf Attachment Side Burner Assembly Side Burner Parts AssemblyBuilt-In Instructions 4 Opening Minimum Additional RequirementsGas Requirements Natural GAS InstallationGeneral Information Tank Information GAS InstallationTank USE Before Testing Pre Operation Leak TestingTesting Before Lighting Lighting the GrillGrill Burner Lighting General Rules Using the GrillGrill Location Do not leave the grill unattended while cookingUsing the Rotisserie & Side Burners Warping from the intense heat of the infrared unitMatch Lighting Rotisserie LightingSide Burner Lighting Care and Maintenance Before Calling Customer Service Troubleshooting Your GrillGeneral Trouble Shooting Problem SolutionFlame is erratic Grill will not light with a match or low heat with dial setTo High position Flare-upsWarranty Limited Lifetime Warranty