Napoleon Fireplaces N415-0232 operating instructions Installation, LP Propane GAS

Page 6

6

INSTALLATION

wARNING! When the appliance is being used with the optional tripod, it must not be situated on a combustible surface, nor can it be located below a combustible overhang.

The glass embers and the burner assembly are shipped together.

Remove the glass embers and burner assembly and check for damage. DO NOT install damaged components. The glass embers may have sharp edges, wear safety glasses and gloves when handling.

Place the appliance on a level/secure surface in desired location. This location must be adjacent to the gas supply line or cylinder.

NOTE: Minimum clearances to combustible construction must be maintained, see "SPECIFICATIONS" section.

WARNING! You must have clear and easy access to the on/off valve AFTER the appliance is installed and connected to the gas supply in order to safely turn off the burner.

THE ON/OFF GAS VALVE IS USED TO TURN THE BURNER ON AND OFF.

NATURAL GAS

Connect the incoming gas supply line to the on/off gas valve of the appliance. Make certain ALL gas connections are tight, turn the on/off valve at the unit slowly to the on position and use soapy water to test for leaks as indicated in the diagrams.

DO NOT USE AN OPEN FLAME.

Burner Assembly

Manual Gas

Valve (on/off)

LP (PROPANE) GAS

Attach cylinder retaining bracket supplied to the base of the cylinder. Then secure to the surface to which it sits. Cylinder should be on a level surface.

This appliance has been designed for use with a 20lb. (9.1kg) or a 30lb (13.6kg) size propane cylinder only (not supplied).

Make sure cylinder valve is in its full off position. (Turn clockwise to stop).

Check cylinder valve features to ensure it has proper external mating threads. (Cylinder Valve Marked:

USE WITH TYPE 1)

Inspect hose shipped with the unit for damage. Never attempt to use damaged or plugged equipment. See your local LP Gas Dealer for repairs.

After inspecting the LP hose shipped with the unit, connect the end with the female fitting on the hose to the male fitting on the on/off gas valve at the end of the flex tube. Tighten fittings using 2 wrenches.

When connecting regulator assembly to the cylinder valve, hand tighten black QCC1 nut clockwise to a positive stop. DO NOT use a wrench to tighten. Use of a wrench may damage the quick closing coupling nut and result in a hazardous condition.

Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage.

Open cylinder valve fully (counter-clockwise). Turn the on/off valve at the unit slowly to the on position and use a soapy water solution to check all connections for leaks as indicated in the diagrams before attempting to light the appliance. If a leak is found, turn tank valve off and do not use the appliance until repairs can be made.

DO NOT USE AN OPEN FLAME.

Burner Assembly

Manual Gas

Valve (on/off)

Cylinder Retaining

Bracket

www.napoleonfireplaces.com

Image 6
Contents Gpfgn GpfgpNapoleon GAS Appliance 5 Year Limited Warranty Conditions and LimitationsSafe Operating Practices General Information Specifications DimensionsInstallation LP Propane GASEnclosures for LP GAS Supply Systems Cylinder Retaining BracketGlass Media Installation Optional MKR Rock InstallationFinishing Lighting Instructions For Your Safety Read Before LightingOperation To Turn OFF GASMaintenance High Elevation InstallationCleaning Stainless Steel Replacements ComponentsPage Service History