Desa CGFB32C installation manual BUILT-IN Firebox, Installation

Page 10

UNVENTED (VENT-FREE) FIREBOX

INSTALLATION

Continued

1.Frame in rough opening. Use dimen- sions shown in Figure 16 for the rough opening. If installing in a corner, use dimensions shown in Figure 17 for the rough opening. The height is 33", which is the same as the wall opening in Figure 16.

2.Install gas piping to firebox location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Connect- ing to Gas Supply in log set owner’s manual.

3.

Carefully set firebox in front of rough

 

opening with back of firebox inside wall

 

opening. IMPORTANT: If installing

 

Brass Trim Kit GA7090, see instructions

 

included with brass trim accessory. You

 

must install shoulder screws now.

4.

If using GA3750 blower accessory, see

 

Installing Built-In Installation of Blower

 

Accessory, page 8.

5.

Attach flexible gas line to log set. See

 

Connecting to Gas Supply in log set

 

owner’s manual.

6.

Carefully insert firebox into rough

 

opening.

7.

Attach firebox to wall studs using nails

 

or wood screws through holes in nail-

 

ing flange (see Figure 18).

8.

Check all gas connections for leaks. See

 

Checking Gas Connections in log set

Figure 15 - Inserting Firebox Into Cabinet

17 3/4"

Mantel

 

BUILT-IN FIREBOX

33" (CGFB32C)

INSTALLATION

34 1/4" (CGFB32NC)

 

 

 

 

 

 

 

 

 

 

 

 

 

Built-in installation of this firebox involves

 

 

 

 

 

 

 

 

 

 

 

 

 

installing firebox into a framed-in enclosure.

 

 

 

 

34 3/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This makes the front of firebox flush with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wall. Optional brass trim (GA7090) is avail-

 

 

 

 

 

 

 

 

 

 

 

 

 

able (see Accessories, page 11) This brass

Figure 16 - Rough Opening for Installing

trim will extend past sides of firebox ap-

in Wall

proximately 1/2 inch. This will cover rough

 

 

 

 

 

 

 

 

 

 

 

 

 

edges of the wall opening. If installing a

 

 

 

 

 

 

 

 

 

 

 

 

 

mantel above the firebox, but you must fol-

 

 

 

 

 

 

 

 

 

 

 

 

 

low the clearances shown in Figure 7, page 7.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow the instructions below to install the

39 3/8"

 

 

 

 

 

 

 

 

 

 

 

 

firebox in this manner.

27 7/8"

 

 

 

34 3/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55 5/8"

 

 

 

 

 

 

 

 

 

Figure 17 - Rough Opening for Installing

 

in Corner

 

Height

Front Width

 

Depth

 

 

 

 

 

 

 

 

 

Model #

Actual

Framing

Actual

 

Framing

Actual

 

Framing

 

 

 

 

 

 

 

 

 

 

 

 

CGFB32C

32 3/ "

33"

34 5/

16

"

34 3/

"

16 11/

16

"

17 3/ "

 

8

 

 

 

4

 

 

 

4

CGFB32NC

33 11/16"

34 1/4"

34 5/16"

34 3/4"

16 11/16"

17 3/4"

owner’s manual.

9. If using optional GA7090 brass trim kit,

install the trim after final finishing and/

or painting of wall. See instructions in-

cluded with brass trim accessory for at-

taching brass trim.

Nails or

Wood

Screws

Nailing Flanges

Figure 18 - Attaching Firebox to Wall Studs

10

103573

Image 10
Contents Unvented VENT-FREE Universal Firebox What to do if YOU Smell GASLocal Codes Safety InformationUnpacking Blower Accessory Product FeaturesProduct Specifications OperationPlanning Locating FireboxAIR for Combustion and Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsMantel Clearances for Conventional Installation InstallationInstallation Clearances Mantel Clearances for Built-In InstallationConventional Installation of Blower Accessory Installing Blower AccessoryInstalling LOG Heater in Firebox Built-In Installation of Blower AccessoryInstalling Fireplace Screen Firebox Installation Using Optional Accessory MantelsInstallation BUILT-IN FireboxReplacement Parts Technical ServiceAccessories Illustrated Parts Breakdown CGFB32CParts List Firebox Parts CentralsWarranty Information Keep this Warranty