Desa CGCFTP CGCFTN installation manual Removing Valve Cover Shield, Installing Blower Assembly

Page 12

12

INSTALLATION

Installing Blower Accessory - GA3450T (Cont.)

INSTALLATION

Continued

Removing Valve Cover Shield

1.Open bottom louver assembly by swinging the assembly down (see Figure 17).

2.Using short Phillips screwdriver, remove the screw under the center of the branch support. Rotate valve cover shield clock- wise and slide out. IMPORTANT: Do not remove shoulder screw on the left side of valve cover shield. Slide the valve cover shield off of the shoulder screw (see Figure 17).

Note: If you do not have a short Phillips screwdriver, the screen, log set, and branch support must be removed so a longer screw- driver may be used. See Connecting Equipment Shutoff Valve to Heater Control, page 15, steps 1 and 2.

Branch Support

 

Shoulder Screw

Remove

Valve Cover

Screw

Shield

 

2

1

Snap Bushings

Bottom Louver

Assembly

 

Figure 17 - Removing Valve Cover Shield

Installing Blower Assembly

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

CAUTION: Verify proper operation after servicing.

Note: If you are using a mantel with your heater, use the following instructions. If your heater is built-in, see For Built-In Installation on page 13.

1.Install snap bushings found in hardware kit into both holes in rear of valve cover shield.

2.Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly.

3.Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 1 and blue wire from terminal 3. Black wire can remain on middle terminal 2 (see Figure 18).

4.Carefully disconnect green and white wires at their insulated connectors.

5.In top of the heater cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 18).

6.Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening above where the valve shield was removed. (see Figure 18).

7.Insert the 4 wire harness into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield (see Figure 18).

8.Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires.

Blower Bracket

 

Assembly

Wire

Wiring Routing

 

Hole in Baffle

Screw

Harness

 

Baffle

Switch

Power

 

Cord

 

3

 

2

 

1

Red

Switch

Plate Blue

Valve Cover

Shield

Box Cover

Wire

Harness

Figure 18 - Installing Blower Bracket Assembly

For..com

111044-01C

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationLocal Codes Product IdentificationProduct Features AssemblyUnpacking AIR for Combustion and Ventilation Providing Adequate VentilationAssembling Hood Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Installation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in WallMantel Clearances for BUILT-IN Installation Optional Mantel InstallationInstalling Blower Accessory GA3450T Removing Upper Louver AssemblyInstalling Blower Assembly Removing Valve Cover ShieldFor Built-In Installation OutletConnecting to GAS Supply Attaching Wood Base to Solid FloorExtension Cord Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleCabinet Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Specifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Models Cgcftp and CgcftnParts List Parts ListParts Centrals Owners Registration Form Postage Required Accessories Warranty Information