Desa LFP33NRA Checking GAS Connections, Pressure Testing Gas Supply Piping System

Page 12

LFP33NRA

UNVENTED NATURAL GAS FIREPLACE

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1. Disconnect appliance with its appliance

main gas valve (control valve) and

equipment shutoff valve from gas sup-

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 19).

2.Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 20). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Open

Equipment

Shutoff

Valve

Closed

Figure 19 - Equipment Shutoff Valve

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Fig- ure 19).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 20). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fire- place, pages 16 and 17). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 17).

 

ply piping system. Pressures in excess

 

of 1/2 psig will damage fireplace gas

 

regulator.

2.

Cap off open end of gas pipe where

 

equipment shutoff valve was connected.

3.

Pressurize supply piping system by ei-

 

ther using compressed air or opening

 

main gas valve located on or near gas

 

meter.

4.

Check all joints of gas supply piping

 

system. Apply mixture of liquid soap

 

and water to gas joints. Bubbles form-

 

ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect fireplace and equipment

 

shutoff valve to gas supply. Check re-

 

connected fittings for leaks.

Manual Gas Valve

Figure 20 - Checking Gas Joints

Equipment

Shutoff

Valve

Gas Meter

12

107063

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information LFP33NRA Unvented Natural GAS FireplaceRemote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Optional Blower AccessoryCheck GAS Type Electrical HookupInstallation Clearances Conventional Fireplace Installation BUILT-IN Fireplace Installation Location of Nailing FlangesInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Installing Logs Installing ScreenOptional Wireless HAND- Held Remote Control Accessory RM4 Installing Batteries for RM4Installing Remote Receiver Unit Installing Batteries in Hand-Held Remote Control UnitInstalling Batteries for Cghrc and Cghrct Series Installing Battery in ReceiverInstalling Battery in Hand-Held Remote Control Unit For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure Optional Remote OperationTo Turn OFF GAS To Appliance Optional Blower OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Wiring Diagram SpecificationsService Hints Technical ServiceReplacement Parts Parts Under WarrantyParts not Under Warranty Parts CentralAccessories Corner MantelGMC11F Series Walnut Finished Hardwood Veneer GMC13F Series Medium Stained Oak VeneerHAND-HELD Remote Control RM4 Blower Accessory GA3750 Series and GA3650T SeriesReceiver and HAND-HELD Remote Control KIT Cghrc Series Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Remote Ready Model LFP33NRAParts List KEY Part Number Description QTYFireplace LFP33NRA Parts List Warranty Information