Harman Stove Company DVC-500 manual Blink Status Details, Stage

Page 31

2 Blink Status Details

DVC 500-C

Firebox Static Pressure

Safety Protocol

The DVC-500 operates with a negative pressure firebox as a safety feature. The control continuously adjusts the draft motor speed to maintain a safe firebox negative static.

NOTE: Observe the intensity of the Draft Motor light on the control panel in comparison with the Feed Motor light when it is on. When the appliance and venting system are clean, the indicator light is much dimmer than the others. This is because there is lower voltage flowing to the draft motor. As ashes build up, the light will get brighter because the draft motor needs to run faster in order to maintain the negative pressure in the firebox. When the indicator light for the draft motor appears as bright as the rest of the lights, it is a good indication that it's time to clean the appliance and the venting.

If the circuit board is flowing full line voltage to the Draft Motor, and the negative pressure in the firebox is too low, the following safety protocol will begin.

Stage 1

When the safety switch senses a loss of negative pressure in the firebox for more than 68 seconds the following happens:

The combustion blower will reduce in speed. During this cool down period the feeder is allowed to opreate. If needed, the feeder can opreate for up to 3 minutes.

After 72 minutes, if the safety switch has not sensed another pressure loss, the unit will automatically go back to the control board setting.

If the safety switch senses a loss of negative pressure anytime during the STAGE 1 Protocol, the unit automatically goes to the STAGE 2 Protocol

Stage 2:

If Stage 1 has already begun and the negative pressure is lost:

The status light will start to blink ( 2 blinks ). The combustion blower and feeder motor will shut off. These motors will remain off for a 5 minute cool- down period. After five minutes, those components will restart at a reduced feed rate ( 30 seconds max.) for 72 minutes.

After 72 minutes, if the safety switch has not sensed another pressure loss, the unit will automatically go back up to Stage 1.

The status light will continue to blink (2 blinks) throughout Stage 1 and Stage 2.

If the safety switch senses a loss of negative pressure anytime during the Stage 2 Protocol, the unit automatically goes to the Stage 3 Protocol.

Stage 3:

During stage 2, if another loss of negative pressure is sensed;

The status light will continue to blink 2 blinks. The Distribution Blower will be cycling "high" to "low" as an audible warning.

The Combustion Blower and Feeder Motor will shut off.

When the unit reaches Stage 3 these motors will not restart.

The Draft Motor will continue to run at maximum voltage, but the fire will go out.

[At any time, the 2 blink status can be reset by disconnecting the power to the unit for a few seconds.]

CAUTION

Resetting a 2 Blink Status likely indicates that service is required.

Clean the appliance and the venting system thoroughly. If the error persists, contact your dealer for more advanced service.

31

Image 31
Contents Harman DVC-500 Coal Stoker Installation & Operating Manual008 Index Never sleep in the same room with any coal burning stove Introduction Assembly Viewing glass Tips On Installation InstallationDo not Install in Mobile Home Sleeping Room Installation Corner Installation Basement InstallationInstallation Installation Vent Pipe Temp Dial ESP ControlPage Operation Testing OperationOperation Wear gloves Daily MaintenanceAsh Removal Setting Ash RemovalSoot and Fly Ash Weekly MaintenanceMaintenance Every 3 Months Prevent Rust End of Heating Season MaintenanceAnnual Service End Of Season Shut Down ListFuel MotorsGrate System Assembly Or Replacement Wiring Diagram Maintenance ScheduleControl and Safety Sensors Control and Safety SensorsRoom Sensor Part number list on following Service PartsNo longer available Stocked at depotCeramic Tile 12 X 6 No longer available At depotSpecifications Blink Status Details DVC 500-C Firebox Static Pressure Safety ProtocolStage CausesAnd/OrReasonsFor2-blinkShutdown DVC-500 Firebox Static Pressure Safety ProtocolHearth & Home Technologies Inc Limited Lifetime WarrantyWarranty Conditions Service & Maintenance Log Proudly Printed On 100% Recycled Paper Signature of Boxer
Related manuals
Manual 36 pages 19.83 Kb

DVC-500 specifications

The Harman Stove Company DVC-500, a prominent model in Harman's lineup, represents the pinnacle of modern pellet stove technology. Designed for both aesthetic appeal and high efficiency, the DVC-500 combines style and functionality to provide an exceptional heating solution for homes.

One of the standout features of the DVC-500 is its user-friendly digital control board. This advanced system allows homeowners to easily adjust settings such as temperature, feed rate, and fan speed, all with the touch of a button. The intuitive interface simplifies operation and enhances the overall user experience. Additionally, the thermostat-compatible feature provides the convenience of maintaining a consistent temperature throughout the home.

The DVC-500 is equipped with a powerful and efficient combustion system that maximizes heat output while minimizing emissions. Its Smart Stove technology continuously monitors and adjusts the combustion process for optimal performance. This ensures that the stove operates at peak efficiency, utilizing less fuel while delivering more heat. As a result, homeowners can enjoy lower energy costs along with an eco-friendlier heating option.

The DVC-500 also boasts a spacious hopper capacity, allowing for extended burn times without the need for frequent refueling. With the ability to hold up to 55 pounds of pellets, users can enjoy hours of consistent warmth and comfort without interruption. The stove's attractive design, available in several finishes, enhances any living space while offering the robust performance expected from Harman products.

Another notable characteristic of the DVC-500 is its easy-to-clean design. The unit features a removable ash pan that simplifies disposal, ensuring that maintenance is hassle-free. Additionally, the heat exchanger is designed for efficient airflow, which enhances the stove's heating capacity while reducing the buildup of soot and debris.

Safety is a critical consideration, and the DVC-500 incorporates several features to ensure peace of mind. The stove includes an integrated safety high-limit switch and a positive-pressure exhaust system that prevents backdraft, making it a reliable choice for any home.

In summary, the Harman Stove Company DVC-500 is a versatile, efficient, and aesthetically pleasing pellet stove that combines advanced technology with ease of use. Its intelligent control systems, high-efficiency combustion, and thoughtful design make it an excellent choice for homeowners seeking a reliable and stylish heating solution. With the DVC-500, Harman continues its legacy of quality craftsmanship and innovative heating solutions.